NUVE NF 200 Скачать руководство пользователя страница 1

 

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. 

Z14.K25.249  REV.NO.:10 REV.DATE:01/2018 

 

 

 

 

NF200 

BENCH TOP CENTRIFUGE 

USER’S MANUAL 

Содержание NF 200

Страница 1: ...NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A Ş Z14 K25 249 REV NO 10 REV DATE 01 2018 NF200 BENCH TOP CENTRIFUGE USER S MANUAL ...

Страница 2: ...lity in the case where the goods are not used in accordance with their proper intent 4 The warranty may not be claimed for damages occurred during the shipment for damages resulting from improper handling or use the defects in maintenance negligence bad functioning of auxiliary equipment in the case of force majeure or accident and incorrect power supply 5 In the event of failure Nüve shall be und...

Страница 3: ...move the warning labels do not operate damaged instrument do not operate the instrument with a damaged cable do not move the instrument during operation In case of a problem contact your Nüve agent for an authorized service or maintenance The validity of the guarantee is subject to compliance with the instructions and precautions described in this manual Nüve reserves the right to improve or chang...

Страница 4: ...5 OPERATING UNIT 8 5 1 OPERATING 8 5 2 DISPLAY AND CONTROL PANEL 8 5 3 MAKING PROGRAM 9 5 3 1 PULSE MODE 10 5 4 SAFETY INTERLOCK SYSTEM 11 5 5 MANUAL LID OPENING 11 SECTION 6 OPERATING PRINCIPLES 12 6 1 PREPARATION OF THE ROTOR TO RUN 12 6 2 LOADING 12 6 3 DRIVE SYSTEM 13 SECTION 7 CLEANING AND PERIODIC MAINTENANCE 13 7 1 PERIODIC MAINTENANCE 13 7 2 STERILIZATION 13 7 3 CORROSION INFORMATION 13 7 ...

Страница 5: ...the centrifuge to operate if the lid is open the lid cannot be opened while the rotor is spinning There are audible and visible alarms to inform the operator when the lid is open when the program ends and when any error condition occurs In case of a power failure the lid could be opened manually by using a manual lid opening tool There is also an observation hole on the lid to check the speed of t...

Страница 6: ...0 rpm Timer set range 1 99 min and hold position Timer set step 1 minute Motor Induction Motor Power Supply 230 V 50 60 Hz Power Consumption 150 W External Dimensions WxDxH mm 280x360x260 Packet Dimensions WxDxH mm 350x420x460 Net Packed weight kg 12 16 2 2 ACCESSORIES FOR NF200 G 03 012 Adaptor for 1 5 2 ml tubes max tube dia 11 mm G 03 014 Adaptor for 7 ml vacuumed non vacuumed tubes max tube di...

Страница 7: ... manual lid opening procedure in the case of power cut or in the case of any error Use only the the spare parts rotors and accessories which are supplied by NUVE Load the rotor according to the explanations in the user s manual Start the device after ensuring the rotor is loaded correctly Do not use the centrifuge in areas which are in explosive danger Do not centrifuge the explosive flammable rad...

Страница 8: ...ccurred during transport Check that the positioning is suitable for users Lift the centrifuge use proper handling equipment if necessary underneath and carry it to its place Check that the centrifuge is stable on its four pads The bench top must be rigid enough to support the weight and vibrations Leave 30 cm free space on the every side of the centrifuge Open the lid by using unlocking tool and c...

Страница 9: ...art the operation 5 2 DISPLAY AND CONTROL PANEL According to the standard IEC 61010 2 020 anyone and any hazardous materials should not be in the 300 mm safety zone while centrifuge is running The centrifuges are designed to operate safely under the following conditions Indoor use only Ambient temperature 5 C to 25 C Maximum relative humidity of 80 for temperature up to 22 C Maximum altitude 2000 ...

Страница 10: ... if the lid indicator lights up 04 LID Indicator Led It turns on if the lid remains open or is not properly closed 05 ENCODER Button This has two functional move Turn clockwise and opposite clockwise reach program menu set value and READY situation By turning the Encoder button increase or decrease values during programming stage When Led is READY situation by pushing Encoder button start device S...

Страница 11: ...arameters for program Close the lid see that the lid open warning led turns off You can reach the desired speed by pressing and holding the Encoder button 6 within the RPM speed limits you have set In the PULSE mode the rotor operates according to the set acceleration and braking values you set While operating in Pulse mode press the Encoder button 6 and start counting from the moment the rotor st...

Страница 12: ... and on device You may display the RPM or RCF value on the speed display during the run by pushing the function button The centrifuge waits at the stand by position with the program values of the last program Please open the lid after every operation otherwise the centrifuge cannot be run again If power failure occurs access to the samples is possible by opening the lid with a special tool Please ...

Страница 13: ...ING Each tube insert must be at the same weight as the one diametrically opposite for balancing In case the number of tubes which will be centrifuged is less than the capacity of the rotor the tubes must be placed in opposite inserts If the number of tubes that will be centrifuged is an odd number use a water filled tube at the same weight for balancing Examples of the proper and improper loading ...

Страница 14: ...equently with the oil provided with the centrifuge Please remove the light oil from the pins and put a small amount of fresh oil every time you grease This will ensure free swinging of the buckets Most of the imbalance problems are mostly raised by the users who do not clean and oil the pins Please do not leave the rotor on a metal surface particularly stainless steel as electrochemical reactions ...

Страница 15: ...lations for disposal have to be carefully observed The instruments and electronic accessories without batteries power packs etc must be disposed off according to the regulations for the disposal of electronic components Batteries power packs and similar power source have to be dismounted from electric electronic parts and disposed off in accordance with applicable local regulations If the centrifu...

Страница 16: ...ailures related error codes shown on the speed display motor starts braking Err 3 The communication between the display main PCB and the motor driver PCB fails Err 4 Motor overheat failure Please wait for the motor to cool down and start the centrifuge again Err 6 Motor driver PCB is defective Lid open This failure occurs when lid is opened during the centrifugation Please close the lid properly a...

Страница 17: ...16 SECTION 10 ELECTRICAL CIRCUIT DIAGRAMS ...

Страница 18: ...17 SECTION 11 WARNING LABEL EARTHED FUSES ...