MCH60
Nuvair
Page 29
www.Nuvair.com
•
Replace the cartridge with a new one.
•
Replace the O-ring (d) with a new one.
•
Re-close the cover (a) and close the clips (c).
Do not carry out these tasks if the compressor has just shut down and is hot; wait for the compressor
to cool down. All maintenance work must be carried out with the compressor OFF and the power
supply lead unplugged from the wall socket.
If the compressor is used in a dusty environment the filter change interval should
be reduced to every 100 hours.
12.0 Transmission Belts
Belt tension must be checked monthly. The transmission belts must be replaced every
500 working hours of the compressor.
12.1 Checking Transmission Belts
To check for proper transmission belt tension (g) exert a pressure of approximately 22 lb
(10 kg) on the belt; check the belts do not flex by more than 1 cm (0.39 in) with respect to
its original position. Should they flex more than this the belts must be replaced.
12.2 Changing Transmission Belts
To replace the transmission belts, proceed as follows:
•
Insert a screwdriver (a) between the first belt (b) and the
pulley (c) of the cooling fan (d).
•
Rotate the fan (d) anticlockwise until the belt comes out of
the pulley groove.
•
Repeat the procedure on the second belt.
•
Change the belts with new ones: make sure the belt
model and length are exact, check that the characteristics
of the new belt are identical to those of the old one.
Содержание MCH60
Страница 1: ...Operation Manual MCH60...
Страница 2: ...MCH60 Nuvair Page 1 www Nuvair com Notes...
Страница 3: ...MCH60 Nuvair Page 2 www Nuvair com Notes...
Страница 37: ...MCH60 Nuvair Page 36 www Nuvair com 19 0 Service Log Date Technician Name Service Performed...
Страница 41: ...MCH60 Nuvair Page 40 www Nuvair com Notes...
Страница 42: ...MCH60 Nuvair Page 41 www Nuvair com 22 0 PLC Wiring Schematics PLC wiring schematics on the following pages...
Страница 43: ...MCH60 Nuvair Page 42 www Nuvair com Notes...