Electrical Connection
WARNING
Connection must only be carried out by suitably trained, qualified and skilled
engineers, in accordance with all regional and local electrical codes.
The appliances are electrically rated for a 208V, 60Hz electrical supply.
Flexeserve Zone® products are provided with a dedicated power cord and appropriate NEMA Style 6 power
coupler rated for the equipment.
The equipment must be connected to a branch circuit protected grounded supply in accordance with
local electrical codes.
Each unit must have its own dedicated power supply.
NOTE
For electrical ratings of the unit, refer to the electrical rating sticker located within the front
valance on the side of the control box. An example is shown below.
It is highly recommended to provide the equipment with an accessible means of isolation external to the
equipment, i.e., a wall isolator switch.
Electrical Ratings
All models are rated 208V (2 wire + Grd, Y).
TOTAL POWER
MODEL
3 TIER UNIT
4 TIER UNIT
5 TIER UNIT
400
2300 W
3000 W
2800 W
600
2300 W
3000 W
2800 W
1000
4500 W
6000 W
5000 W
WARNING
For all types of installation, ensure that the power cord is in a safe position. Under no
circumstances should any electrical cables or power points be installed directly in contact
with any part of the unit or pose a risk to safety.
If the mains power lead becomes damaged, isolate the equipment and remove from
service immediately until a replacement is fitted by a suitably trained, qualified and
skilled engineer, in accordance with all regional and local electrical codes.
Electrical rating