CHIME WIRING INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Musical Door Chime
MODEL LB-55
MODEL LB-60 PROGRAMMABLE CHIME
This musical door chime may be connected to a NuTone
Radio-Intercom System to provide the intercom speakers
with the chime tones. If it is acceptable to have the chime
tones
override
the radio and intercom (chime heard as well
as radio and intercom,) connect chime to intercom as shown
on the primary instruction sheet for the chime. If you wish the
radio and intercom to be
muted
(silenced) when the chime
is playing, the connections between the chime and intercom
must be as shown here. If you wish the
door speakers,
as
well as the inside/patio speakers to receive the chime, see
pages 2 and 3 for wiring information.
*SPECIAL NOTE: In IMA-806 systems connected for
MUTING as shown in this page and page 4, it should be
considered that music will remain muted after a chime
tune completion – until either an “END CALL” switch is
pressed or the automatic end call timer resets the IM-806
control circuit.
COMMON
(CENTER)
INPUT
(COPPER)
1
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
100 OHM
RESISTOR
CHIME
INTERCOM
MASTER
CHIME
CHIME
INTERCOM
MASTER
METAL
CHASSIS
GROUND
SCREW
CHIME
BLACK
1
2
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
100 OHM
RESISTOR
CHIME
CHIME
N2510
YELLOW
OR BRN/
YELLOW
PAIR
CHIME
ANY
BLK/WHT
1
2
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
22K OHM
RESISTOR
GROUND
REMOTE
HOOK-UPS
(BLK)
1
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
6800 OHM
RESISTOR
CHIME
IM-806
EXT.
CHIME
* SEE SPECIAL NOTE
}
EXT.
CHIME
CHIME
IMA-516
RED/WHT
CHIME
BLACK
1
2
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
100 OHM
RESISTOR
CHIME
COMMON
(CENTER)
INPUT
(COPPER)
ORANGE
WIRE
(PLUG P1,
PIN 7)
1
2
I-COM
EXT.
SPKR.
I-COM
CONTROL
100 OHM
RESISTOR
DOOR SPEAKER CONTROLLED BY “DOOR ON/OFF”
SWITCH ON IMA-203 MASTER
MODEL IMA-303, IMA-323, OR IMD-313
MODEL SM-428 OR IMA-406
MODEL IM-806
MODEL IMA-516
MODEL IMA-203
MODEL N2510 (2500 SYSTEM)