WARNING  

 

 

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING:

1.  Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact 

the manufacturer at the address or telephone 

number listed in the warranty.

2.  Before servicing or cleaning unit, switch power 

off at service panel and lock the service discon-

necting means to prevent power from being 

switched on accidentally. When the service dis-

connecting means cannot be locked, securely 

fasten a prominent warning device, such as a 

tag, to the service panel.

3.  Installation work and electrical wiring must be 

done by a qualified person(s) in accordance 

with all applicable codes and standards, includ-

ing fire-rated construction codes and standards.

4. Sufficient air is needed for proper combus-

tion and exhausting of gases through the flue 

(chimney) of fuel burning equipment to prevent 

backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards 

such as those published by the National Fire 

Protection Association (NFPA), and the Ameri-

can Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local 

code authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6. Ducted fans must always be vented to the 

outdoors.

7.  If this unit is to be installed over a tub or shower, 

it must be marked as appropriate for the appli-

cation and be connected to a GFCI (Ground Fault 

Circuit Interrupter) - protected branch circuit.

8.  Never place a switch where it can be reached 

from a tub or shower.

9. This unit must be grounded.

CAUTION

1.  For general ventilating use only. Do not use to 

exhaust hazardous or explosive materials and 

vapors.

2.  This product is designed for ceiling installation 

only. This product is designed for installation 

in ceilings up to a 12/12 pitch. Ductwork must 

point up. DO NOT MOUNT THIS PRODUCT IN 

A WALL.

3.  To avoid motor bearing damage and noisy and/

or unbalanced impellers, keep drywall spray, 

construction dust, etc. off power unit.

4.  Please read specification label on product for 

further information and requirements.

Installer: Leave this manual with the 

homeowner. Homeowner: Use and Care 

information on page 4.

READ AND SAVE

THESE INSTRUCTIONS

TYPICAL INSTALLATIONS

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

HOUSING MOUNTED TO ADDITIONAL FRAMING 

Discharge 90

0

 to joists.

HOUSING MOUNTED DIRECTLY TO JOIST 

2x6 (or larger)  

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING

TABS

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

GRILLE

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

MOUNTING

TABS

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

"

I

"

JOIST

"

I

"

JOIST

GRILLE

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING TABS

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

GRILLE

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

HOUSING

MOUNTING TABS

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

"

I

"

JOIST

"

I

"

JOIST

GRILLE

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

*

 Additional framing must be a 2x6 (minimum height).

*

*

*

*

AVERTISSEMENT

    

OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN 

DE RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC 

ÉLECTRIQUE OU DE BLESSURES CORPORELLES :

1.  N’utilisez cet appareil que de la manière prévue par le 

fabricant. Si vous avez des questions, communiquez 

avec le fabricant à l’adresse ou au numéro de 

téléphone indiqués dans la garantie.

2.  Avant de procéder à l’entretien ou au nettoyage de 

l’appareil, coupez l’alimentation du panneau électrique 

et verrouillez l’interrupteur principal afin d’empêcher 

que le courant ne soit accidentellement rétabli. S’il 

est impossible de verrouiller l’interrupteur principal, 

fixez solidement un message d’avertissement, par 

exemple une étiquette, sur le panneau électrique.

3.  La pose de l’appareil et les travaux d’électricité 

doivent être effectués par des personnes qualifiées 

conformément à la réglementation en vigueur, 

notamment les normes de la construction ayant trait 

à la protection contre les incendies.

4.  Pour éviter les refoulements, l’apport d’air doit 

être suffisant pour brûler les gaz produits par 

les appareils à combustion et les évacuer dans 

le conduit de fumée (cheminée). Respectez les 

directives du fabricant de l’appareil de chauffage et 

les normes de sécurité, notamment celles publiées 

par la National Fire Protection Association (NFPA), 

l’American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE) et les codes des 

autorités locales.

5.  Veillez à ne pas endommager le câblage électrique 

ou d’autres équipements non apparents lors de la 

découpe ou du perçage du mur ou du plafond.

6.  Les ventilateurs canalisés doivent toujours rejeter 

l’air à l’extérieur.

7.  Si cet appareil doit être installé au-dessus d’une 

enceinte de baignoire ou de douche, il doit comporter 

les mentions appropriées pour ces utilisations et doit 

être branché sur un circuit de dérivation protégé par 

un disjoncteur de mise à la terre.

8.  Ne jamais placer un interrupteur de sorte que l’on 

puisse l’atteindre d’une baignoire ou d’une douche.

9.  Cet appareil doit être relié à une mise à la terre.

ATTENTION

 

1.  Pour ventilation générale uniquement. N’utilisez 

pas cet appareil pour évacuer des matières ou des 

vapeurs dangereuses ou explosives.

2.  Ce produit ne convient qu’à une pose dans un plafond 

et peut être installé dans un plafond dont la pente 

n’excède pas 12/12.  Les conduits doivent pointer 

vers le haut. CE PRODUIT NE PEUT PAS ÊTRE POSÉ 

DANS UN MUR.

3.  Pour éviter d’endommager les roulements du 

moteur, de déséquilibrer les pales ou de les rendre 

bruyantes, débarrassez l’appareil de la poussière de 

plâtre, de construction, etc.

4.  Veuillez lire l’étiquette de spécifications du produit 

pour obtenir plus de renseignements, notamment 

sur les exigences.

Installateur : Veuillez remettre ce 

manuel au propriétaire. Propriétaire : 

Voir le mode d’utilisation et d’entretien 

à la page 4.

!

LIRE CES DIRECTIVES  

ET LES CONSERVER

*