MODEL:  625N244SNCL, 625N244BZCL 

    

   RECESSED MOUNTED,  

 

                LOCKING STEEL 

                BATH CABINETS

 

INSTALLATION of CABINET

 

1.  Carefully remove all packing material.  Place hardware  

 

 

packages and shelves aside until needed.  

 

2.  Determine desired location of cabinet on wall.  Mark  

 

 

wall to show wall opening size (see dimension chart).   

 

 

Generally, the recommended height to the center of the  

 

 

cabinet is 64” from the floor.  (Fig. 1)

 

3.  CAUTION:  Wall studs, plumbing or electrical lines  

 

 

that interfere must be removed or relocated.  Cut wall  

 

 

opening, being careful not to damage the surrounding  

 

 

wall surface.  Insert framing to support all plaster  

 

 

board edges.

 

4.  Prepare the mounting screws by placing the screws  

 

 

into the  plastic bases.  (Fig. 2)

 

5.  Note:  For ease of installation, an additional person is  

 

      recommended.  Insert cabinet into wall opening.  

 

 

(Fig. 3)  Ensure adequate clearance on the lock side 

             of the cabinet to insert and remove the key from the                    

             lock.Ensure the cabinet is plumb and level.  If      

 

       necessary use a carpenter’s level and shim corners of  

 

 

cabinet.  Secure to wall studs through the four (4)  

 

 

mounting holes inside cabinet, using the screws that  

 

 

have been placed into the plastic bases.  (Fig. 3)  Do  

 

 

not over tighten the mounting screws as  the body side  

 

 

wall may bend and prevent proper shelf installation.   

 

 

Only tighten screws until they are flush with the body.

 

6.    Snap the screw covers over the screw bases.  (Fig.4)

 

7.  Carefully slide shelves into the cabinet body.

 

REPLACEMENT of EXISTING RECESSED CABINET

 

1.  Remove existing cabinet from the wall.  Measure the  

 

 

rough wall opening.  The opening must be the size  

 

 

shown (dimension chart) above.  If the opening is the  

 

 

proper size, the cabinet will easily fit between existing  

 

      studs.  Then, continue to Step 3.  If the opening    

 

 

is too large, new framing may be required.  If the  

 

 

opening is too small, the existing wall cut out may need  

 

 

to be enlarged.  The services of a professional    

 

 

carpenter are highly recommended for any wall    

 

 

modifications.

 

 

NOTE:  The rough wall opening must be free of all 

 

 

obstructions.  If plumbing or electrical lines interfere  

 

 

with the wall opening, they must be relocated.  This  

 

 

must be done in accordance with local and national  

 

 

codes preferably by a plumber and/or electrician.

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS

  

 MODEL   

  WALL OPENING     OVERALL SIZE

      NO.  

        W    H     D           W          H        D  

625N244SNCL     14       24    3-1/4   15-3/4   25-1/2    5                   

625N244BZCL     14       24    3-1/4   15-3/4   25-1/ 2   5 

For help, call us toll 

free!

1-800-325-8351

Register your product online at www.nutone.com/register

Fig. 2

Fig. 3

MIRROR CARE

   

•  Use only  clean warm water and a clean, soft,      

      lint-free cloth.

    •  DO NOT USE cleaners that contain solutions of  

      ammonia, vinegar, or chlorine.

    •  DO NOT USE powdered cleansers or steel wool.

    •  Never spray cleaning agent directly on mirror,    

      especially on exposed edges and mirror backing.   

      Apply cleaner to soft cloth and wipe mirror.  Dry  

      mirror thoroughly.

    •  Keep mirror dry.  A well ventilated bath room is   

      important.