MODEL: 625N244SNCL, 625N244BZCL
RECESSED MOUNTED,
LOCKING STEEL
BATH CABINETS
INSTALLATION of CABINET
1. Carefully remove all packing material. Place hardware
packages and shelves aside until needed.
2. Determine desired location of cabinet on wall. Mark
wall to show wall opening size (see dimension chart).
Generally, the recommended height to the center of the
cabinet is 64” from the floor. (Fig. 1)
3. CAUTION: Wall studs, plumbing or electrical lines
that interfere must be removed or relocated. Cut wall
opening, being careful not to damage the surrounding
wall surface. Insert framing to support all plaster
board edges.
4. Prepare the mounting screws by placing the screws
into the plastic bases. (Fig. 2)
5. Note: For ease of installation, an additional person is
recommended. Insert cabinet into wall opening.
(Fig. 3) Ensure adequate clearance on the lock side
of the cabinet to insert and remove the key from the
lock.Ensure the cabinet is plumb and level. If
necessary use a carpenter’s level and shim corners of
cabinet. Secure to wall studs through the four (4)
mounting holes inside cabinet, using the screws that
have been placed into the plastic bases. (Fig. 3) Do
not over tighten the mounting screws as the body side
wall may bend and prevent proper shelf installation.
Only tighten screws until they are flush with the body.
6. Snap the screw covers over the screw bases. (Fig.4)
7. Carefully slide shelves into the cabinet body.
REPLACEMENT of EXISTING RECESSED CABINET
1. Remove existing cabinet from the wall. Measure the
rough wall opening. The opening must be the size
shown (dimension chart) above. If the opening is the
proper size, the cabinet will easily fit between existing
studs. Then, continue to Step 3. If the opening
is too large, new framing may be required. If the
opening is too small, the existing wall cut out may need
to be enlarged. The services of a professional
carpenter are highly recommended for any wall
modifications.
NOTE: The rough wall opening must be free of all
obstructions. If plumbing or electrical lines interfere
with the wall opening, they must be relocated. This
must be done in accordance with local and national
codes preferably by a plumber and/or electrician.
INSTALLATION INSTRUCTIONS
MODEL
WALL OPENING OVERALL SIZE
NO.
W H D W H D
625N244SNCL 14 24 3-1/4 15-3/4 25-1/2 5
625N244BZCL 14 24 3-1/4 15-3/4 25-1/ 2 5
For help, call us toll
free!
1-800-325-8351
Register your product online at www.nutone.com/register
Fig. 2
Fig. 3
MIRROR CARE
• Use only clean warm water and a clean, soft,
lint-free cloth.
• DO NOT USE cleaners that contain solutions of
ammonia, vinegar, or chlorine.
• DO NOT USE powdered cleansers or steel wool.
• Never spray cleaning agent directly on mirror,
especially on exposed edges and mirror backing.
Apply cleaner to soft cloth and wipe mirror. Dry
mirror thoroughly.
• Keep mirror dry. A well ventilated bath room is
important.
Fig. 4
Fig. 1