9.
Fill and Vent the Hydraulic Systems
The lift is preinstalled at the factory and is delivered with the hoses connected to the unit. After unpacking the power
unit, loosen the allen head screws to remove the back cover and fill the power unit with a high-quality hydraulic oil with
a viscosity of AW32. The required oil volume is approximately 2 gallons. After filling, the oil must be near the top of the
oil dipstick or
to the “fill” line
.
•
Make certain the lift area is free of all bystanders.
•
Check all hose connections for tightness, most leaks occur at connection points
[TR5]
Danger! The lift is pre-tested at the factory, so the hoses and
cylinders are already full of oil. Over-filling the system before
bleeding and lowering can cause the tank to overflow due to the
excess fluid.
This procedure must always be completely carried out, meaning
first fill and then vent. This is the only method of balancing a lift
with HyperFlow
10.
Installation and Initiation
10.1.
Safety Checks
The safety check is necessary to guarantee safe operation of the Lift during use.
Safety checks should occur as follows: after installation, before initial startup, after initial startup, at least once a year,
and any time modifications have been made to the Lift.
A.
TOOLS NEEDED FOR THE INSTALLATION
•
Chalk line
•
Marking Pen
•
Tape Measure
•
4’ Level
•
Hacksaw
•
Hammer Drill
•
½” & ¼” Masonry Bits
•
Metric Hex Key Set
•
Hammer
•
SAE Wrench Set
•
Transmission funnel
Danger! Before the installation of the Lift, secure the installation
area to prevent access by unauthorized persons.
Attention!
Before beginning installation, familiarize yourself with
the entire installation process and with the “Foundation Plan”
(Appendix 1)
.