Be careful: Unroll the sheathed cable for lowering with its whole length and go outside
of the emergency area.
• Remove the cover of the canister.
• Position an obstacle (piece of wood max. 5mm) between the cover and the canister so
the emergency cable can be moved easily.
• Unroll the rope of the ball valve the emergency lowering.
• The operator must stand outside of the dangerous area.
• It is only possible to pull the cable in one direction.
• Observe the reaction of the lift and the vehicle.
• In case of danger, let go of the cable.
• Lower the lift into the lowest position.
Do not work with the automotive lift, if the lift is not in a faultless condition.
7.Inspection and Maintenance
Before conducting maintenance work, preparations must be made to ensure that
during maintenance and repair work there is no risk to the safety of people working on
or around the lift and also that there is no risk of damage to equipment being used on
or around the lift.
To guarantee the utmost availability and to ensure that the lift remains functional, maintenance
work contracts are organised between our clients and their local retailers.
A service must be performed at regular intervals of 3 months through the operator in
accordance with following service manual. If the lift is in continuous operation or in a dirty
environment, the maintenance rate must be increased.
During daily operation the lift must be closely observed to ensure that it is functioning correctly.
In the case of malfunction or leakage the technical service must be informed.
7.1 Maintenance plan of the lift
• Before beginning any maintenance work isolate the power supply. Secure the main switch
(lock it). Secure the danger area around the automotive lift and secure the lift against
unintentional lowering.
• Clean the piston-rod using compressed air.
Grease the piston rods with a high capacity lipid (approx. 5 g of S2 DIN51503 KE2G
available from the Renolit Company.
Clean and check the stripper of the guidance-piston.
• Grease the lubricate nipples with a multipurpose lipid. (example: Auto Top 2000 LTD. Agip)
• Clean and lubricate the moving parts of the lift (hinge bolts, sliding pieces, sliding surfaces)
grease with a multipurpose lipid (example: Auto Top 2000 LTD. Agip).
• Check the hydraulic tubes for leakage.
• Remove all fluids in the canister. After it, seal the cover again.
• Check the oil level. Fill the tank with a clean, high quality oil (32 cst) (e.g.g. HLP 32 LTD.
OEST Company)
• The hydraulic oil has to be changed at least once a year. To change the oil, lower the lift into
its lowest position. Empty all tanks and refill with clean oil, see chapter 3.1 .
Содержание 2.35 TSK
Страница 9: ...Operating Instruction and Documentation 2 35 TSK 9 2 5 Declaration of conformity...
Страница 11: ...Operating Instruction and Documentation 2 35 TSK 11 3 3 Data sheet...
Страница 12: ...Operating Instruction and Documentation 2 35 TSK 12 3 4 Foundation diagram drawing...
Страница 13: ...Operating Instruction and Documentation 2 35 TSK 13 3 5 Hydraulic diagram drawing...
Страница 14: ...Operating Instruction and Documentation 2 35 TSK 14 3 6 Electrical diagram drawing...
Страница 15: ...Operating Instruction and Documentation 2 35 TSK 15...
Страница 16: ...Operating Instruction and Documentation 2 35 TSK 16...
Страница 17: ...Operating Instruction and Documentation 2 35 TSK 17...