General Notes

If the system is serving a room
containing a fuel burning appliance
of a non-balanced flue design, it is
the responsibility of the installer to
ensure that sufficient replacement
air is provided to prevent products
of combustion from being drawn
down the flue when the fan/ light
unit is operating.
The unit should not be sited where
it would be subject to a direct
source of heat in excess of 40

o

C.

Once fitted into ceiling void or loft
space, do not cover light body, fan
or 12V power supply unit with any
insulating materials.
Minimum void height when fitting
into ceiling space is 250mm.

ISOLATION
Note that the unit must be
provided with a means of iso-
lation (by others) for mainte-
nance purposes etc. An RCD
trip device must be included
between the power supply
unit and the mains if the unit
is fitted in zone 1 as defined
in IEE regulations.
Refer to Wiring Instructions
overleaf.

Installation
IMPORTANT

The installation must be carried
out by qualified personnel in
accordance with the appropriate
authority and conforming to all
statutory and governing regula-
tions 

eg. IEE, COHSE etc.

Cut a hole in the ceiling to the size
indicated and thread through the two red
12V Power Supply unit cables.

To wire in the light, lift off the cover.
Loosen the clamp on the case side. Bring in
the two red 12V cables and wire as shown.

Push one end of the 90° bend onto the
light unit and click fit.

Pull the ducting down through the ceiling
and attach with the tie provided.

Push the complete assembly up through
the hole. Make sure the lamp wiring is not
impeded. Unclip internal intake finisher.

Mark and plug three holes using the three
fixing holes on the light unit. Secure by
using three No. 6 countersunk screws.

Alternatively, attach the fixing fingers to
the light unit using long screws provided.

Push the light unit through the ceiling and
twist the fingers outwards.

Then tighten the fixing fingers against the
ceiling (do not overtighten).To fit the lamp
see overleaf. Refit the internal finisher

.

Fit the reducer to the end of the ducting
using ties provided.

Install the 230V fan (instructions included
with fan) and connect to 100mm ducting.

Prepare hole through wall or soffit. Push
through unattached end of the flexduct
attach it to the grille spigot using the tie.

Fix grille back plate using plugs and screws.
Snap on the external grille. Note: If exhaust
is through a wall, ensure the grille louvres
slope downwards.

Coding

NE25BT  

This system kit includes a Genie/Tops
230V duct mouinted fan with an integral
run on timer.
GENIE-S or TOPS-S
The fan is fitted with a backdraught shutter
and is operated by a remote switch (switch
by others).

NE25BTX   

This system kit includes a two speed
Genie/Tops 230V  duct mouinted fan. Fan is
designed to run continuously at a low duty
(with very low noise levels) and has a ‘boost’
facility via a remote switch (switch by
others).
GENIE-X or TOPS-X
NB: No backdraught shutter.

Inlet grille with 
12V light unit 

125mm Flexiduct

100mm Flexiduct

100mm Flexiduct

Reducer

Dynoties

115mm Bend

Power Supply
230V / 12V

Red 12V wires 
to Light unit

External Grille

230V 
supply

230V supply

INSTALLATION

Neonaire 

NE25BT/BTX

Shower Fan & Light

The EMC directive: 89/336/EEC
with modification 92/31/EEC
The low voltage directive 73/23/EEC

Leaflet 671139

SEPTEMBER 2001

1

2

3

145 mm diameter

ceiling aperture

4

100mm Flexiduct

100mm Flexiduc

Reducer

230V supply

230V Fan

Lamp 
wires

5

6

7

8

9

10

11

12

13

NuAire Limited   
Western Industrial Estate
Caerphilly, United Kingdom
CF83 1XH
Telephone: 029 2088 5911
Facsimile: 029 2088 7033
Email: [email protected]
www.nuaire.co.uk

100mm Flexiduct

125mm Flexiduct

Reducer

Technical or commercial considerations may,

from time to time, make it necessary to 

alter the design, performance and 

dimensions of equipment and the right 

is reserved to make such changes 

without prior notice.