background image

1

nuaire.co.uk 

029 2085 8400

14. 03. 19. Leaflet Number  671778

The EMC Directive 
2014/30/EU
The Low Voltage 
Directive
2014/35/EU

NA-E-100 12V Range (50Hz only)

SELV Axial Wall/Ceiling Mounted Toilet and Bathroom Fans

Installation and Maintenance

IPX4

1.0 Introduction

These high quality extractor fans are designed to provide effective 
ventilation. To achieve this, please read these instructions carefully BEFORE 
installing the fan unit. Failure to comply with these instructions could 
reduce both the life and performance of the product and may invalidate the 
warranty.

This product is suitable for use with a maximum of 1.5m of rigid ducting. 
(Flexible ducting is not recommended).

This appliance can be used by children aged from 8 years and above and persons 
with reduced physical, sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction concerning use of 
the appliance in a safe way and understand the hazards involved. Cleaning and 
user maintenance should not be made by children without supervision.

2.0 Installation

The installation must be completed by competent persons in accordance with 
good industry practice and should conform to all governing and statutory bodies 
i.e. IEE, CIBSE, HVCA etc.

Before commencing any work read the following instructions carefully and 
ensure you have the necessary competency to complete the work safely.

3.0 Dimensions

Isolation - Before commencing work, make sure that the unit, 

switched live and any controls are electrically isolated from the mains 

supply. If in doubt, consult an electrician.

IMPORTANT

1. Select a suitable position for the fan that keeps the duct as short and as 

straight as possible (ideally on the ceiling or on a wall within 400mm of the 
ceiling).

2. Cut a hole in the wall to suit the outside diameter of the ducting or wall-liner. 

Install the duct or wall-liner taking care to seal at both ends between it and 
the wall using proprietary waterproof mastic.

3. Remove the front cover of the fan by pulling the fan back plate straight off 

(Fig. 1).

4. Position the fan in the duct and mark the four retaining screw positions 

through the backplate. Fit screw anchors suitable for the wall construction.

5. Remove the central terminal cover by first removing the central Posidriv® 

retaining screw (Fig. 2).

6. Unclip and remove the fan wall-mounting plate (Fig. 3).

7. Complete the wiring by following the relevant wiring diagram on the 

following page (for cable entry detail see Fig. 4).

8. Reassemble using these instructions in reverse.

Figure 1. Removing front cover

Figure 3. Remove wall-mounting plate

Figure 5. Fan dimensions (mm)

Figure 2. Remove central terminal cover

Figure 4. Cable entry point