Isolation - Before commencing work make sure that the unit,
switched live and Nuaire control are electrically isolated from
the mains supply.
1
11. 05. 17. Leaflet Number 671741
Figure 3. Fan Dimensions (mm)
170
170
110
9
72
The EMC Directive
2014/3
0
/EU
The Low Voltage
Directive
2014/35/EU
Fig. 1a. Removing front facia.
Fig. 1b. remove 4 screws and front half.
Fig. 2. Pass the supply cable through the cable entry point.
Genie Plus GP-100 Range
Centrifugal Wall/Ceiling Mounted
Toilet and Bathroom Fans
Installation and Maintenance
99
69
IPX4
1.0 Introduction
These high quality extractor fans are designed to provide effective
ventilation. To achieve this, please read these instructions carefully
BEFORE installing the fan unit. Failure to comply with these
instructions could reduce both the life and performance of the
product and may invalidate the warranty.
This product is suitable for use with up to a maximum of 6.0m of
rigid ducting. (Flexible ducting is not recommended).
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
2.0 Installation
The installation must be completed by competent persons in
accordance with good industry practice and should conform to all
governing and statutory bodies i.e. IEE, CIBSE, HVCA etc.
Before commencing any work read the following instructions carefully
and ensure you have the necessary competency to complete the work
safely.
1. Select a suitable position for the fan that keeps the duct as short
and as straight as possible (ideally on the ceiling or on a wall within
400mm of the ceiling).
2. Cut a hole in the wall to suit the outside diameter of the ducting or
wall-liner. Install the duct or wall-liner taking care to seal at both
ends between it and the wall using proprietary waterproof mastic.
If required, connect further ducting to the wall-liner, sealing
between each joint or fitting.
3. Remove the front cover of the fan by pulling straight off the fan
body (Fig. 1a and 1b).
4. Remove and retain the bag containing four Posidriv® screws for
retaining the body moulding to the back-plate (Fig. 1b) and the
cable clamp and screws.
5. Locate the fan back-plate into the wall-liner/duct and mark the four
retaining screw positions (Fig. 2). Fit screw anchors suitable for
the wall construction.
6. Install the fan taking care to pass the supply cable through the cable
entry point in the fan back-plate moulding (Fig. 2).
7. Complete the wiring by following the relevant wiring diagram on
the following page (Fig. 4).
8. Assemble the fan body to the back-plate and clip on the front cover.