Installation
and Maintenance
Introduction
The Genie / TOPS range of toilet and bathroom
units has been specifically designed to ventilate
small rooms such as toilets, bathrooms,
cloakrooms etc.
Measuring a compact 200mm x 173mm x 120mm
the units deliver 25 l/s via a 100mm dia. outlet
fitted to the rear face.
Air entering the unit passes through a washable
filter fitted to the front cover.
Anti- backdraught shutters, retained in the closed
position when fan is not running, are fitted to the
base plate.
Motor has sealed, self-lubricating bearings and
'Heatseeker' thermal overload protection.
The fan / motor assembly is retained by spring
clips to simplify maintenance.
As a safety feature the fan / motor assembly is
automatically disconnected when the electronic
control module is removed.
All models incorporate a LED run indicator.
The unit is actuated by a passive infra red PIR
detector, mounted on the front cover. An integral
run on timer is fitted which is adjustable from
0-20 mins run on.
Nuaire Limited
Western Industrial Estate
Caerphilly, Mid - Glamorgan CF83 1XH
United Kingdom
Telephone 02920 885911
Facsimile No. 02920 887033
Email: [email protected]
Typical Installations
Semi - recessed mounted - ceiling
Surface mounted - wall
Fig.2 Typical Installations
Installation
(To be carried out by qualified personnel only)
Surface Mounting
Note. It is assumed that a solid non reverberant
mounting position has been selected and the
necessary passages for ductwork from the outlet
spigot, as well as the electrical connection prepared.
It is also assumed that compatible ductwork has
been installed.
Isolate the electrical supply by switching off at
mains and removing fuses.
1. Remove cover/grille assembly by depressing
the top & bottom retaining tabs.
2. Remove the plug-in electronic control module .
(Fig. 4)
3. Remove the fan / motor assembly by pulling
aside the two spring clips.
4. Place the unit in the desired mounting
position,connect the ductwork and feed the
cable through the cable entry.
Leaflet No. 670684
JULY 2001
1
Fig 1. General view.
-P.I.R
Toilet & Bathroom Extract Fan
surface & semi recessed mounting*
NUAIRE
Semi recessed
finishing plate
*
A optional window mounting kit is
available for this unit, code ref:
WINKIT
.
When installing the unit in a window, use the
instructions supplied with the kit.