NuAire GENIE Скачать руководство пользователя страница 1

Installation 

and Maintenance

Introduction

The Genie / TOPS range of toilet and bathroom
units has been specifically designed to ventilate
small rooms such as toilets, bathrooms, 
cloakrooms etc. 
Measuring a compact 200mm x 173mm x 120mm
the units deliver 25 l/s  via a 100mm dia. outlet 
fitted to the rear face.  
Air entering the unit passes through a washable 
filter fitted to the front cover.
Anti- backdraught shutters, retained in the closed
position when fan is not running, are fitted to the
base plate.
Motor has sealed, self-lubricating bearings and
'Heatseeker' thermal overload protection. 
The fan / motor assembly is retained by spring
clips to simplify maintenance. 

As a safety feature the fan / motor assembly is 
automatically disconnected when the electronic
control module is removed. 
All models incorporate a LED run indicator. 

The unit is actuated by a passive infra red PIR
detector, mounted on the front cover.  An integral
run on timer is fitted which is adjustable from 
0-20 mins run on.

Nuaire Limited
Western Industrial Estate
Caerphilly, Mid - Glamorgan CF83 1XH
United Kingdom
Telephone  02920  885911
Facsimile No. 02920  887033
Email: [email protected]

Typical Installations

Semi - recessed  mounted - ceiling

Surface mounted - wall

Fig.2  Typical Installations

Installation

(To be carried out by qualified personnel only)

Surface Mounting

Note. It is assumed that a solid non reverberant
mounting position has been selected and the 
necessary passages for ductwork from the outlet 
spigot, as well as the electrical connection prepared.
It is also assumed that compatible ductwork has
been installed.

Isolate the  electrical supply by switching off at
mains and removing fuses. 

1.  Remove cover/grille assembly by  depressing 

the top & bottom retaining tabs.  

2.  Remove the plug-in electronic control module .  

(Fig. 4)

3.  Remove the fan / motor assembly by pulling  

aside the two spring clips.

4.  Place the unit in the desired mounting 

position,connect the  ductwork and feed the            
cable through the cable entry.

Leaflet No. 670684
JULY 2001

1

Fig 1. General view.

-P.I.R

Toilet & Bathroom Extract Fan

surface & semi recessed mounting*

NUAIRE

Semi recessed 
finishing plate

A optional window mounting kit is 

available for this unit, code ref: 

WINKIT

.

When installing the unit in a window, use the 
instructions supplied with the kit.