Low Energy Positive Input Ventilation Unit

DRI-ECOSMART/ 1 or 2

Installation and Maintenance Details

The EMC Directive 
89/336/EEC   
With modification 
92/31/EEC  
The Low Voltage 
directive  73/23/EEC

1

Leaflet Number 671346 October 2006

Power

Status

Figure 1. General view of unit in a loft. 
(Shown located on AV mounts).

User control panel, located in the home.

Please note: 

1. Only the items shown shaded
are supplied as standard with
the unit. 
All other installation materials
(see table on page 3) must be
purchased separately by the
installer.

2. The 4 temperature sensors 
(one for each of the air inlet 
locations and one for the 
home itself) and associated
sensor cables (15m long) are
also supplied with the unit.

3. The cable (10m long) 
connecting the unit to the user
control is also supplied.

1.0  Important notes to installers

The successful operation of the unit depends entirely upon 
installation and ongoing maintenance being carried out strictly 
in accordance with these instructions.

Please read this guide in its entirety before installation and then
repeat the exercise step by set to ensure satisfactory completion.

Suitably qualified persons may achieve installation of the unit, 
however the provision of the electrical supply and the connection of
the unit to the mains supply should only be carried out by a qualified
electrician.

The unit can be installed in a home with a “cold roof” construction.
These instructions are limited to installation in a home with a
“cold roof”. “Warm roofs” vary considerably and advice should
be sought from Nuaire on an individual basis.

2.0  General description

The unit is a unique Low Energy Positive Input Ventilation (LEPIV)
unit. Unlike conventional LEPIV units which only draw in external 
air via the loft in a “cold roof’, the unit is capable of drawing in 
external air from different roof locations via three air inlet spigots
each fitted with their own low energy open/close damper. (See fig. 1). 

The units airflow and the opening/closing of each air inlet damper 
is controlled via an integral intelligent control system that measures,
and appropriately responds to, temperatures at the various air inlet 
locations, the home itself, the “target temperature” selected by the
occupants on the user control panel provided and the delivered air
temperature into the home.

There are two standard versions of the unit 
available. Each is coded/identified as follows:

DRI-ECOSMART/1

Unit supplied with control panel providing 
On/Off/Auto/Boost/Target Temperature 
selection and Unit/Filter Status Indication. 

DRI-ECOSMART/2

Unit supplied with control panel providing 

Target Temperature selection and Unit/Filter 
Status Indication. 

Содержание DRI-ECOSMART/1

Страница 1: ...sons may achieve installation of the unit however the provision of the electrical supply and the connection of the unit to the mains supply should only be carried out by a qualified electrician The un...

Страница 2: ...own the longest lengths of the hallway or landing Obstructions within 1m of the diffuser will cause a poor airflow pattern and unacceptable draughts Up to two sides of the diffuser may be closed off u...

Страница 3: ...d by the installer see 8 4 c or roof tile vents by others and ducting supplied by the installer see 8 5 The following installation materials not supplied with the unit can be purchased separately by t...

Страница 4: ...m area Timber support nailed short side to rafter across full width of plenum area Figure 7 Section through plenum 320mm Insulated ducting to unit Insulated ducting fitted over spigot and sealed with...

Страница 5: ...insulated ducting connected to unit spigot using dynotie connector 150mm dia pipe Part No GB250 T200 Insulated duct formed over pipe and sealed with dynotie connector 199 x 215 x 20mm white plastic wa...

Страница 6: ...the home Select a position unaffected directly by heating radiators or possible draughts from opening windows Using a small screwdriver pierce a hole in the corner of the ceiling and push the end of t...

Страница 7: ...b and two press buttons under the flap which enable the fan to be switched off or the airflow to be boosted to its maximum duty DRI ECOSMART 2 The user control is similar to the one shown above but ex...

Страница 8: ...e unit to allow access for maintenance 15 0 Warranty The units 5 year warranty starts from the day of delivery and includes parts and labour 16 0 Service Enquiries Nuaire can assist you in all aspects...

Отзывы: