05. 08. 20. Document Number  671943

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

DRI-ECO-NOX-HEAT

Whole House Ventilation Unit with RF Enabled 
Hall Control, Heating & Carbon Filters 

Installation Manual

EMC Directive

 

2014/30/EU

LVD Directive

 

2014/35/EU

1.0 SAFETY INFORMATION

• 

The provision of the electrical supply and the connection of the unit to the mains must be 
carried out by a qualified electrician.

• 

Isolate from power supply before removing any covers. During installation / maintenance ensure 
all covers are fitted before switching on the mains supply. 

• 

All-pole disconnection from the mains as shown in the wiring diagram must be incorporated 
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with 
latest edition of the wiring regulations.

• 

This unit must be earthed.

• 

Ensure the flexible duct (maximum length 2m) is connected to the base unit by inserting the 
duct over the outlet duct and fix in place using the supplied cable tie. When installing the duct 
to the heater unit, insert the duct over the back of the heater, over the protruding screw heads 
(3mm from the face of the duct) and fasten the cable tie below the screws. 

• 

This ensures that the duct will be held on securely, check all duct joints are air tight. 

• 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard.

• 

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of 
gas or other fuel-burning appliances.

• 

This appliance should not be used by children or persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the safe use of the appliance by a person responsible for their safety. 
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried 
out by children.

• 

In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance 
must not be supplied through an external switching device, such as a timer, or connected to a 
circuit that is regularly switched on and off by the utility. 

• 

The fan unit is supplied with a fused spur. The three core mains cable from the fan unit should 
be connected to a fixed wiring installation, via the spur, in accordance with current IEE wiring 
regulations. 

• 

The heater unit must be connected to the ceiling vent and fan unit using the 3 looms that 
protrude from the heater module. 

• 

The CO2 sensor requires a 230V power supply. Remove the front panel as per the humidity 
sensor and release the terminal cover via a fixing lug on the rear of the sensor. Refer to the 
wiring diagram provided and connect the supply to the terminal box. Finally the sensor may be 
mounted to the wall (screws are not provided). 

Содержание DRI-ECO-NOX-HEAT

Страница 1: ...ed by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or...

Страница 2: ...emperature Heat Recovery strategy shall be achieved via a sensor located in the unit and shall improve energy performance accordingly This unit has all the controls for the fan in the ceiling vent all...

Страница 3: ...s are air tight IMPORTANT Isolate from power supply before removing any covers During installation maintenance ensure all covers are fitted before switching on the mains supply IMPORTANT CAUTION In or...

Страница 4: ...er Installation Place the carbon filter over the central hole as seen in Figure and clamp in place using the filter retaining plate Secure the retaining plate using the four domed screws provided Fit...

Страница 5: ...ing vent will show the start up pattern for two minutes and the unit will begin running at speed 6 In this time you can change the temperature setting by pressing and holding the up switch The display...

Страница 6: ...n the rear of the PCB and release the fixing plate Reassemble the remaining components and press into place an audible click will be heard 1x CR 2032 battery is provided and expected lifetime is 10 ye...

Страница 7: ...tton on the ceiling diffuser control panel once to exit the start up sequence 3 Press and hold both the UP and DOWN buttons for between 20 30 seconds then release optimum time is 25 seconds a single h...

Страница 8: ...plastic and widely recycled Cardboard packaging wood used filters and other paper components can be largely recycled or fully processed in energy from waste centres Remaining Items can be further seg...

Отзывы: