8
5. - INSTALLATION REQUIREMENTS
THIS APPLIANCE MUST BE INSTALLED AND SERVICED BY A PROPERLY QUALIFIED, (IN ACCORDANCE WITH LOCAL &
NATIONAL CODES), INSTALLATION ENGINEER.
It is the Law in the UK that All gas appliances are installed by a competent person in accordance with the GAS SAFETY
(INSTALLATION AND USE) REGULATIONS 1998 (As amended), the relevant British Standards for Installation work, Building Reg-
ulations, Codes of Practice and these Instructions. In the UK a Registered Installer is deemed competent. In the
Republic of Ireland, all Irish Standards, Local Codes and Bord Gais recommendations should be adhered to.
The Installation should also be carried out in accordance with the following where relevant:
1. BS5871 Part 2 2. BS5440 Parts 1 & 2 3. BS6461 Parts 1 & 2 4. BS6891 5. BS8303 6. BS EN 1856 7. BS715
Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development
Department.
In the Republic of Ireland Installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of
Practice, these Manufacturers Instructions and any Rules In Force.
Particular Reference should be made to the Ventilation Requirements, for the UK this Appliance would not normally require any
additional purpose provided ventilation, for the Republic of Ireland ventilation should be in accordance with IS813 Domestic Gas
Installations.
Failure to comply with the above could leave the Installer Liable to Prosecution and Invalidate the Warranty.
IMPORTANT
BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY. THESE INSTRUCTIONS
SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING. PRIOR TO INSTALLATION ENSURE
THAT THE GAS TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA BADGE.
6. - APPLIANCE DATA
a.
Gas Type: See Data Plate (Natural Gas at 20mbar or Propane 37mbar).
b.
Burner Pressure: Natural Gas 18.0mbar cold. Propane 35.8mbar cold.
c.
Control Systems: Manual or High Level (Push Button) or Thermatronic (Fully Sequential) Control System operated by Handset
pointed at Receiver.
d.
Fire Safety: Oxygen Depletion & Flame Failure Device.
e.
Ignition: Manual-Integral Piezo Igniter, High Level-Integral Piezo Igniter, Thermatronic-Full Sequential Control.
f.
Inlet Connection: 8mm Compression Fitting to Gas Isolation Elbow.
g.
Categories: I2H & I3P
h.
Injector: Natural Gas (G20) - 480 Multi hole. Propane (G31) - 210 Single hole.
i.
Heat Input: High: Natural Gas (G20) - 6.95kW Gross (6.26kW Nett). Propane (G31) - 6.65kW Gross (6.12kW Nett).
j.
Heat Input: Low: Natural Gas (G20) - 2.0kW Gross (1.8kW Nett). Propane (G31) - 2.0Kw Gross (1.8kW Nett).
k.
Efficiency Class: 2. The Efficiency of this appliance has been measured as specified in BS7977-1:2009, the results obtained
were: Natural Gas 58.6% Gross (65.0% Nett), Propane 56.6% Gross (65.0%Nett). The test data has been certified by BSI
Group (0086) and can be used in the UK Government’s Standard Assessment Procedure (SAP) for Energy Rating of Dwellings.
l.
Heat Output: High: Natural Gas (G20) - 4.1kW. Propane (G31) - 3.9kW.
m.
Heat Output: Low: Natural Gas (G20) - 1.1kW . Propane (G31) - 1.1kW.
n.
Pilot ODS Type: Natural Gas (G20) - P448 . Propane (G31) - P449 .