Nu-Flame Warranty and Repair Procedure for The Hotbox H.E. 

 
The Nu-Flame Hotbox H.E. is guaranteed for 1 year from the date of purchase.  During that time our guarantee is to send  
replacement parts for a fire that proves to have faulty components or workmanship.  At our option we may decide to repair, or 
replace, at no charge a fire that proves to have faulty components or workmanship. 
 

Telephone Help Line.

  In the event of a problem with a fire the first course of action should be to telephone our technical  

department on 020 8254 6802 during normal working hours 9 - 5.30 Monday - Friday (closed 1 - 1.30).  If possible this should be 
done before the installer leaves site as we may well be able to resolve the problem over the phone, and, in any event it will save 
the installer a return visit to site.  If we are not able to resolve the problem over the phone we will decide the most expedient way 
of resolving the problem and this is likely to be to send replacement parts.  It is possible that we will ask you to return the fire or 
parts of the fire and if this is the case we will log your details and give you a return reference number. 
 

Returning the Fire and parts thereof.  

After assessment we might consider it best to return part of the appliance, such as 

the burner only, for testing. In this example the burner can then be thoroughly inspected and any signs of installation faults can be  
reported back to you.  After any repair work is carried out the flow rates can be checked and re-set if necessary in order to fully  
comply with CE approval.  

Note:

 It is a condition of the warranty that you do not return any parts to us unless we request you to 

do so.  For example if we request that the burner only is returned and you send the entire appliance, the fuel bed and other items 
could be damaged of lost during the return delivery to us.  We will not be liable for any such breakages, or losses. 
 
Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval  
during the warranty period. 
 
This guarantee is given subject to the following provisions: 
 
1.  That the installation is carried out by a GAS SAFE registered installer (we may require their registration details). 
2.  That the appliance is installed and used in accordance with our Installation & User instructions. 
3.  That the gas supply pressure at the appliance is not more than 3mbar below the gas pressure stated on the data plate when 

the appliance is running on high flame, with any other major gas appliances also running. 

4.  That the fireplace and flue system conform to relevant local codes, building regulations and British Standards. 
5.  This Guarantee is not transferable and relates to the original installation only. 
6.  The appliance has not been subject to misuse or accident or been modified or repaired by any person other than the 
       authorised employee or authorised representative of Nu-Flame Ltd. 
7.  The Record Data section on the front of the Installation & Servicing Instructions is to be completed on installation. 
8.  Nu-Flame Ltd accepts no liability for any consequential loss or damage arising from the use or failure of the product or any  
 

information provided, including, but not limited to, economic or financial loss, damage to peripheral equipment or products, 
loss of use, productivity or time. 

9.  That the serial no. data plate on the burner is intact. 
 
This guarantee in no way reduces your statutory rights. 
 
This guarantee supersedes any previously published guarantees. 
 

Chargeable Repairs During And After The Warranty Period 

If a repair is chargeable during the warranty period, due to installation faults we will inform you and where possible give you a 
quote, or if this is not possible, a price guide before starting work.  We cannot always give a firm cost until we commence the  
repair as it is not always possible to tell which components have been damaged. 

Содержание THE HOTBOX H.E.

Страница 1: ...INSTALLATION SERVICING INSTRUCTIONS ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Road Sutton Surrey SM3 9PF...

Страница 2: ...of Infrared Control System 26 Guarantee 27 BOX CONTENTS The Fire comes in 1 box containing the Fire with chosen Control and Fitting kit see next page for fitting kit contents plus the chosen Fuel Bed...

Страница 3: ...gs 1 Flue Restrictor 2 No 8 x 10mm pointed self tapping screws for the restrictor 4 Magnets for holding Front Trim on 1 2 050mm length of 6mm x 4mm self adhesive silicone sealing strip 1 10mm Back Nut...

Страница 4: ...if the oxygen level in the room is depleted due to lack of primary air or obstructed flue blocked chimney that would lead to incomplete combustion of the gas It must not be tampered with and only rep...

Страница 5: ...rim Push Buttons Press the lowest button to gradually reduce the gas flow from Maximum to the Pre Set Minimum Setting you will hear the motor turning the control Keeping the Lower Button depressed wil...

Страница 6: ...replacement is recommended at the beginning of each heating season or when an acoustic error message sounds during ignition b Error Message Long signals 0 8 second tone 0 2 second break during igniti...

Страница 7: ...use abrasive cleaners For Stainless Steel finishes we recommend a small amount of Baby Oil 4 SERVICING a The fire should be Serviced Annually in accordance with the Gas Safety Uses Regulations b This...

Страница 8: ...THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE...

Страница 9: ...he chimney flue is continuous from inlet to termination l Ensure that the chimney flue is structurally sound so that combustion products do NOT come into contact with combustible materials outside the...

Страница 10: ...antee Therefore it is important that all gas pipes must be purged of both air and debris i If you suspect that there may still be dirt and or debris in the gas system fit a filter in the pipeline befo...

Страница 11: ...to thoroughly dry out before Installation IMPORTANT NOTE Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the builders opening or fireplace as t...

Страница 12: ...T FLUE FIREPLACES AND THE FOLLOWING DETERMINES THE MINIMUM REQUIREMENTS AND THE ADDITIONAL BUILDING WORK REQUIRED 13 INSTALLATION INTO A PRE CAST FLUE Rebated Fire Surround Rated 150 C or Purpose Buil...

Страница 13: ...The Surround must cater for a minimum flat surface around the Fireplace Opening allowing 625mm high by 530mm wide This is essential in order to achieve a good seal between the face of the surround an...

Страница 14: ...gh the Property g The Flue Box must be Insulated on its top and sides with 50mm thick Non Combustible Fibreglass Insulation or Equivalent h If plaster board is used in front of the flue box it must be...

Страница 15: ...uld be a maximum of 75mm as anything deeper will reduce convection air and the efficiency of the fire For deeper non combustible shelves they must be raised a further 25mm for every extra 25mm of dept...

Страница 16: ...LL APPLICATION USING MARBLE SLATE OR STONE SLIPS SHELF IMPORTANT NOTE Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the builders opening or f...

Страница 17: ...is very important that a good seal is achieved between the back of the Fire s outer frame and the front of the fireplace back panel for safety reasons and to achieve maximum efficiency Take the self...

Страница 18: ...fixing is not sound the Rawlplug Eyebolt will be pulled out and the fire will not be sealed to the Fireplace Opening Note With the minimum depth fireplace enclosure it may be necessary to sink the Ey...

Страница 19: ...may notice small white marks on the Matrix This is part of the production process TIP When fitting the Coals Pebbles leave gaps between as this helps achieve the best effect TIP Pebbles only The Long...

Страница 20: ...oals on top of the 3 large Rear Coals Note The centre coal to be edge on and pushed up against the fireback to make it the highest coal For Pebbles Layout Choosing different colours and textures fit 3...

Страница 21: ...t 1 either side of the Large Coal on top of the Triangular Coals and sit the remainder 2 either side and behind the Small C Coals just placed For Pebble Layout Fit 6 Small Pebbles Fit 1 either side of...

Страница 22: ...ow to warm up for 5 minutes and then using a lit smoke match joss stick or similar place centrally just under the inner canopy as shown below The majority of the smoke must be drawn under the Fire Can...

Страница 23: ...for Servicing b Check the operation and ignition of the fire before servicing c Ensure the fire is cold before proceeding d Lay a dust sheet on the floor before proceeding e Carry out a gas soundness...

Страница 24: ...locking the flame to the thermocouple b Check the thermocouple is tightly connected to the control c Change the pilot assembly as a new thermocouple may be required d With the Manual System or 2 Butto...

Страница 25: ...stablish how long the fire stays alight then repeat the Spillage Test around this time d For the Thermatronic System check that the Control is functioning correctly as detailed in Section 21 2 specifi...

Страница 26: ...26 22 DIAGRAM OF INFRARED CONTROL SYSTEM...

Страница 27: ...ry to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during the war...

Отзывы: