
10
11. - GAS SUPPLY
It Is Recommended to Check The Next Section as Building Work May Affect the Gas Supply Routing.
a.
Carry out a gas soundness test before working on the gas supply.
b.
Gas supply provision should be made in accordance with the latest Gas Safety (Installation and Use) Regulations as amended.
c.
Confirm that the fire has been supplied for the correct gas to be used by checking the Data Badge in the base of the fire.
d.
A route for a concealed gas supply is provided through a hole in the rear of the fire, at a position of 95mm to the left of the centre
of the fire and 49mm up from the base of the Fireplace/Builders opening. An isolation elbow is provided at the control inlet. Your
8mm gas supply pipe needs to protrude through the back of the convector box by approximately 190mm to achieve a neat
connection onto the back of the isolator elbow on the burner. (This applies to All Control Options.)
e.
Where the gas supply passes through walls, floors, voids, concrete and wall cavities the supply should be sleeved.
f.
Determine the gas supply pipe size required taking into account any other gas appliances.
g.
Determine where the gas supply pipe needs to terminate and fit the 8mm compression isolation/pressure test elbow provided.
h.
In common with all other gas appliances, dirt and debris in the gas system can block the valve and gas injectors on this
appliance, and faults caused by this are not covered by the guarantee.
Therefore it is important that all gas pipes
must
be purged of both air and debris.
i
If you suspect that there may still be dirt and/or debris in the gas system, fit a filter in the pipeline, before the gas isolation/
pressure test elbow.
J.
Do
not
use jointing compound on any compression fittings on the fire. The use of jointing compound on the compression joints
on this appliance will possibly invalidate the guarantee, as it can get into the control mechanism and cause a malfunction.
k.
Seal off the isolation/pressure test elbow and check all gas connections for gas soundness before proceeding to fit the fire
.
! IMPORTANT NOTE !
Always reseal the pressure test point and check that it is gas tight.
(This accounts for a lot of
recalls.)
The Installation Application Options Are:
12.0 Installation into a Class 1 or Lined Flue with a 150ºC rated Fire Surround fitted into a Suitable
Fireplace Opening or 16” Chairbrick.
13.0 Installation into a Pre-cast Flue Fireplace. (Rebated Fire Surround Rated 150ºC or Purpose
Built Surround Extension.)
14.0 Installation into a BS 715 Shallow Flue Box with Twin Wall 5”Flue, False Chimney Breast with
either a 150ºC rated Fire Surround or part way up the wall as a Hole in the Wall Installation with
Slips & Shelf.
15.0 Installation into a Hole in the Wall application with a Class 1 or Lined Flue requiring a Purpose
made Builders Opening.
Sections 12 - 15 are for the various Installation Applications -
Only one will apply.
! IMPORTANT NOTE !
The chosen installation should have
been predetermined and arranged before installing the fire.
Ensure you refer to the section relevant to your requirement.
Содержание THE HOTBOX H.E.
Страница 26: ...26 22 DIAGRAM OF INFRARED CONTROL SYSTEM...