11. - GAS SUPPLY 
It Is Recommended to Check The Next Section as Building Work May Affect the Gas Supply Routing. 

a. 

Carry out a gas soundness test before working on the gas supply. 

b. 

Gas supply provision should be made in accordance with the latest Gas Safety (Installation and Use) Regulations as amended. 

c. 

Confirm that the fire has been supplied for the correct gas to be used by checking the Data Badge in the base of the fire. 

d. 

A route for a concealed gas supply is provided through a hole in the rear of the fire, at a position of 95mm to the left of the centre 

 

of the fire and 49mm up from the base of the Fireplace/Builders opening. An isolation elbow is provided at the control inlet.  Your 

 

8mm gas supply pipe needs to protrude through the back of the convector box by approximately 190mm to achieve a neat       
connection onto the back of the isolator elbow on the burner.  (This applies to All Control Options.) 

e. 

Where the gas supply passes through walls, floors, voids, concrete and wall cavities the supply should be sleeved. 

f.

  Determine the gas supply pipe size required taking into account any other gas appliances. 

g.

  Determine where the gas supply pipe needs to terminate and fit the 8mm compression isolation/pressure test elbow provided. 

h. 

In common with all other gas appliances, dirt and debris in the gas system can block the valve and gas injectors on this  

 

appliance, and faults caused by this are not covered by the guarantee. 

 

Therefore it is important that all gas pipes 

must 

be purged of both air and debris. 

i  

If you suspect that there may still be dirt and/or debris in the gas system, fit a filter in the pipeline, before the gas isolation/
pressure test elbow. 

J. 

Do 

not 

use jointing compound on any compression fittings on the fire. The use of jointing compound on the compression joints 

on this appliance will possibly invalidate the guarantee, as it can get into the control mechanism and cause a malfunction. 

k.

  Seal off the isolation/pressure test elbow and check all gas connections for gas soundness before proceeding to fit the fire

 

 

! IMPORTANT NOTE !  

Always reseal the pressure test point and check that it is gas tight.

  

(This accounts for a lot of 

 

 

 

 

 

recalls.)

 

 

 
 
 
 

The Installation Application Options Are: 

 

12.0  Installation into a Class 1 or Lined Flue with a 150ºC rated Fire Surround fitted into a Suitable 

Fireplace Opening or 16” Chairbrick. 

 

13.0  Installation into a Pre-cast Flue Fireplace. (Rebated Fire Surround Rated 150ºC or Purpose 

Built Surround Extension.) 

 

14.0  Installation into a BS 715 Shallow Flue Box with Twin Wall 5”Flue, False Chimney Breast with 

either a 150ºC rated Fire Surround or part way up the wall as a Hole in the Wall Installation with 
Slips & Shelf. 

 

15.0  Installation into a Hole in the Wall application with a Class 1 or Lined Flue requiring a Purpose 

  made Builders Opening. 

 
 
 
 
 
 
 
 
 
 
 

Sections 12 - 15 are for the various Installation Applications -  

Only one will apply.

 

 

! IMPORTANT NOTE ! 

The chosen installation should have 

been predetermined and arranged before installing the fire.

 

 

Ensure you refer to the section relevant to your requirement. 

Содержание THE HOTBOX H.E.

Страница 1: ...INSTALLATION SERVICING INSTRUCTIONS ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Road Sutton Surrey SM3 9PF...

Страница 2: ...of Infrared Control System 26 Guarantee 27 BOX CONTENTS The Fire comes in 1 box containing the Fire with chosen Control and Fitting kit see next page for fitting kit contents plus the chosen Fuel Bed...

Страница 3: ...gs 1 Flue Restrictor 2 No 8 x 10mm pointed self tapping screws for the restrictor 4 Magnets for holding Front Trim on 1 2 050mm length of 6mm x 4mm self adhesive silicone sealing strip 1 10mm Back Nut...

Страница 4: ...if the oxygen level in the room is depleted due to lack of primary air or obstructed flue blocked chimney that would lead to incomplete combustion of the gas It must not be tampered with and only rep...

Страница 5: ...rim Push Buttons Press the lowest button to gradually reduce the gas flow from Maximum to the Pre Set Minimum Setting you will hear the motor turning the control Keeping the Lower Button depressed wil...

Страница 6: ...replacement is recommended at the beginning of each heating season or when an acoustic error message sounds during ignition b Error Message Long signals 0 8 second tone 0 2 second break during igniti...

Страница 7: ...use abrasive cleaners For Stainless Steel finishes we recommend a small amount of Baby Oil 4 SERVICING a The fire should be Serviced Annually in accordance with the Gas Safety Uses Regulations b This...

Страница 8: ...THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE...

Страница 9: ...he chimney flue is continuous from inlet to termination l Ensure that the chimney flue is structurally sound so that combustion products do NOT come into contact with combustible materials outside the...

Страница 10: ...antee Therefore it is important that all gas pipes must be purged of both air and debris i If you suspect that there may still be dirt and or debris in the gas system fit a filter in the pipeline befo...

Страница 11: ...to thoroughly dry out before Installation IMPORTANT NOTE Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the builders opening or fireplace as t...

Страница 12: ...T FLUE FIREPLACES AND THE FOLLOWING DETERMINES THE MINIMUM REQUIREMENTS AND THE ADDITIONAL BUILDING WORK REQUIRED 13 INSTALLATION INTO A PRE CAST FLUE Rebated Fire Surround Rated 150 C or Purpose Buil...

Страница 13: ...The Surround must cater for a minimum flat surface around the Fireplace Opening allowing 625mm high by 530mm wide This is essential in order to achieve a good seal between the face of the surround an...

Страница 14: ...gh the Property g The Flue Box must be Insulated on its top and sides with 50mm thick Non Combustible Fibreglass Insulation or Equivalent h If plaster board is used in front of the flue box it must be...

Страница 15: ...uld be a maximum of 75mm as anything deeper will reduce convection air and the efficiency of the fire For deeper non combustible shelves they must be raised a further 25mm for every extra 25mm of dept...

Страница 16: ...LL APPLICATION USING MARBLE SLATE OR STONE SLIPS SHELF IMPORTANT NOTE Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the builders opening or f...

Страница 17: ...is very important that a good seal is achieved between the back of the Fire s outer frame and the front of the fireplace back panel for safety reasons and to achieve maximum efficiency Take the self...

Страница 18: ...fixing is not sound the Rawlplug Eyebolt will be pulled out and the fire will not be sealed to the Fireplace Opening Note With the minimum depth fireplace enclosure it may be necessary to sink the Ey...

Страница 19: ...may notice small white marks on the Matrix This is part of the production process TIP When fitting the Coals Pebbles leave gaps between as this helps achieve the best effect TIP Pebbles only The Long...

Страница 20: ...oals on top of the 3 large Rear Coals Note The centre coal to be edge on and pushed up against the fireback to make it the highest coal For Pebbles Layout Choosing different colours and textures fit 3...

Страница 21: ...t 1 either side of the Large Coal on top of the Triangular Coals and sit the remainder 2 either side and behind the Small C Coals just placed For Pebble Layout Fit 6 Small Pebbles Fit 1 either side of...

Страница 22: ...ow to warm up for 5 minutes and then using a lit smoke match joss stick or similar place centrally just under the inner canopy as shown below The majority of the smoke must be drawn under the Fire Can...

Страница 23: ...for Servicing b Check the operation and ignition of the fire before servicing c Ensure the fire is cold before proceeding d Lay a dust sheet on the floor before proceeding e Carry out a gas soundness...

Страница 24: ...locking the flame to the thermocouple b Check the thermocouple is tightly connected to the control c Change the pilot assembly as a new thermocouple may be required d With the Manual System or 2 Butto...

Страница 25: ...stablish how long the fire stays alight then repeat the Spillage Test around this time d For the Thermatronic System check that the Control is functioning correctly as detailed in Section 21 2 specifi...

Страница 26: ...26 22 DIAGRAM OF INFRARED CONTROL SYSTEM...

Страница 27: ...ry to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during the war...

Отзывы: