Rev 6.1 November 1, 2016
14
3.
CONTROL OPTIONS & CONTROL WIRING
Your machine is equipped for remote controls. Options include humidity sensing, off-on control,
intermittent and continuous modes, recirculation as well as high speed control from dehumidistat or
timer(s). Your unit can accommodate both ES Series and Windsor Series or other 24 VAC controls.
Both types of control may be used in the same installation, with ONE type of central control (12 VDC or
24 VAC).Various means of controlling the system are described below.
ES Series Controls (12 VDC)
3.1.1.
ES Tx and Mx Controls
ES Series T
x
and M
x
controls are equipped with a touch pad and 3 LED’s. The touch pad is used to
select mode of operation or turn the appliance off. The LED’s indicate mode of operation. ES T
x
and M
x
controls can be used in virtually any number, and can be wired in
series or in parallel
.
ES T
x
and M
x
Controls and their Functions
Control
Description
Functions
ES-T1
20-40-60 minute timer
Initiates timed high speed when unit is in low speed or standby.
ES-M1
Off, Standby, Low,
High
Full-time in standby, low speed or high speed.
ES-M2
Off, Standby, Low, 20
Low/ 40 Standby
Full-time in standby, low speed, or a cycle of 20 min. low speed
followed by 40 minutes of standby.
ES-M3
Off, Standby, Low, 20
Low/40 Recirc (low)
Full-time in standby, low speed, or a cycle of 20 min. low speed
followed by 40 minutes of low speed recirculation.
ES-M4
Off, Standby, Low,
Recirc.
Full-time in standby, low speed, or low speed recirculation.