NTI XTENDEX Series ST-C5RS-LCRS232 Скачать руководство пользователя страница 1

 

 

Man249 Rev. 9/25/15 

                 
                 

 
 

 

ST-C5RS-LC 

RS232 EXTENDER  

Installation and Operation Manual 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

XTENDEX

®

 

Series

 

ST-C5RS-LC

RS232 Extender

Содержание XTENDEX Series ST-C5RS-LCRS232

Страница 1: ...Man249 Rev 9 25 15 ST C5RS LC RS232 EXTENDER Installation and Operation Manual XTENDEX Series ST C5RS LC RS232 Extender...

Страница 2: ...o 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without res...

Страница 3: ...Plug in and Boot Up 5 DIN Rail Mounting 6 Technical Specifications 7 Interconnection Cable Wiring Method 7 Warranty Information 8 TABLE OF FIGURES Figure 1 Connect Local extender to CPU 4 Figure 2 Con...

Страница 4: ...ered devices Powered by attached devices though DB9 serial cable If additional power is required a 9 30VDC power supply can be wired to the screw terminal pair sold separately Regulatory Approvals CE...

Страница 5: ...6 7 cable 4 Terminal Block for connecting 9 30VDC power supply if required optional sold separately 5 RS232 Connector 9D female for connecting to the RS232 port on the CPU Master Unit or serial devic...

Страница 6: ...c All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging from a connection may interfere with the quality of...

Страница 7: ...n the Master see label on back of extender and the serial port on the back of the CPU or other serial controlling device Figure 1 Connect Local extender to CPU 2 Connect the supplied 6 inch 9DB male t...

Страница 8: ...should illuminate Try sending communication between the CPU and the serially controlled device The CPU and device should each react as if they were directly connected to each other Note The yellow Tx...

Страница 9: ...o holes on the back of the extender screws are provided Then set the extender on the rail against the spring clips side first apply a small amount of pressure and rotate the extender up to lock the ra...

Страница 10: ...C Operating humidity 5 95 Non Condensing Dimensions WxDxH In Local or Remote 1 63x3 13x0 88 Drivers required none Regulatory Approvals CE FCC RoHS INTERCONNECTION CABLE WIRING METHOD The connection c...

Страница 11: ...ate of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or return...