background image

 

 

      

MAN050  Rev 2/5/14

 

                 

 
 
 

 

SM-nXm-C5AV-LCD 

 

Audio/Video Matrix Switch via CAT5

 

Installation and Operation Manual 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Used with NTI ST-C5VA-600 (XTENDEX

TM

) (NOT INCLUDED) 

 

VEEMUX

®

Series

 

Содержание VEEMUX SM-nXm-C5AV-LCD

Страница 1: ...MAN050 Rev 2 5 14 SM nXm C5AV LCD Audio Video Matrix Switch via CAT5 Installation and Operation Manual Used with NTI ST C5VA 600 XTENDEXTM NOT INCLUDED VEEMUX Series...

Страница 2: ...ording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to chang...

Страница 3: ...laying Audio Level Digital VU Meter 13 RS232 Interface 14 Matrix Switcher s Control Program For Windows 9X NT 2000 and XP 15 Telnet Interface Port 2000 16 Telnet Interface Port 2005 17 Command Summary...

Страница 4: ...ure 16 Set IP Address from LCD and keypad 12 Figure 17 Wserver Timeout Period 13 Figure 18 Adjust LCD contrast 13 Figure 19 View Output audio level 13 Figure 20 Web interface Welcome page 20 Figure 21...

Страница 5: ...ent with additional manual control assures maximum video quality at lengths of up to 600 feet All connections between local sources and remote displays can be made using CAT5 CAT5e or CAT6 UTP cable E...

Страница 6: ...wer switch used to power the VEEMUX On Off 4 IEC Power Connector for attachment of power cord 5 Fuseholder for replaceable 2A 250V overcurrent protection fuse fuses mounted inside case on some models...

Страница 7: ...video port on the CPU or KVM switch 7 Audio Plug 3 5mm stereo audio plug for connecting to CPU audio line out 8 Audio Jack 3 5mm stereo audio jack for connecting to remote speakers 9 9VDC 1 0A connect...

Страница 8: ...the VGA port on the back of the CPU b Connect the black 3 5mm stereo plug into the line out spkr or headphones jack on the back of the CPU or other audio video source i e VCR DVD player etc Notes If...

Страница 9: ...le end should snap into place Note If an RJ45 wall outlet is being used connect the other end of the extension cable to the RJ45 wall outlet WARNING Never connect the ST C5VA 600 Extender to an Ethern...

Страница 10: ...he Cat 5 port on the Remote Unit See Fig 3 When properly inserted the CAT5 cable end should snap into place Note If an RJ45 wall outlet is being used connect the other end of the extension cable to th...

Страница 11: ...or of both the Remote and Local Units should illuminate indicating that a proper power connection has been made to them See Fig 4 Figure 4 Connect the AC adapters Note The yellow LED on each RJ45 conn...

Страница 12: ...described on page 6 5 Connect the powercord as shown in Fig 6 Figure 6 Attach ST C5VA 600 Remote Unit to VEEMUX Rear View of SM 16X16 C5AV LCD 9 10 11 12 13 14 15 16 AV OUT AV IN AV OUT 9 10 11 12 13...

Страница 13: ...the terminal to the DB9 female connector on the VEEMUX The cable should be wired straight through pin 1 to pin 1 etc See Fig 9 The user terminal will control the VEEMUX via the RS232 interface page 1...

Страница 14: ...econds see Fig 11 Figure 11 VEEMUX start up message on LCD During this time the VEEMUX retrieves its switch settings from memory the startup configuration is retrieved from stored configuration 0 Pres...

Страница 15: ...9 ENTER Also used to enter the periods in a IP address or Subnet Mask Configuration Menu By pressing the Menu key the display will show the following configuration menu Figure 13 Configuration menu o...

Страница 16: ...he user to enter a new IP address A new IP address is entered using number keys and the key for periods The user must press Enter to save the new IP address If the new address is invalid the user will...

Страница 17: ...n the LCD display Figure 18 Adjust LCD contrast After adjusting the contrast the user can press Enter to store the new contrast value or press Esc to return the contrast to its original value Video Ad...

Страница 18: ...48 00 96 00 Factory default is 9 600 RV SW 00 CR string 0 CR Read NTI Version String RU SW CR IP OP CR Read Unit Size EA SW ip CR Set the IP address ip is in xxx xxx xxx xxx format number of digits i...

Страница 19: ...Matrix Switcher s Control Program To install the Matrix Switcher s Control Program after downloading 1 Locate the Setup exe in the directory the program was downloaded to and double click on it 2 Foll...

Страница 20: ...ost Quit telnet session CS nn mm CR Connect one Input Port nn To one Output Port mm CA nn CR Connect All Outputs To Input RO nn CR mm CR Read Connection For Output Returns the number of the input mm c...

Страница 21: ...followed by a CR Command Detail RU Read Unit Size Command Byte 1 Byte2 Byte3 R 0x52 U 0x55 CR 0x0D Response Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 r 0x72 u 0x75 Space 0x20 Out...

Страница 22: ...output ports to the specified input port SS_01 Enable Auto Status Mode Command Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 S 0x53 S 0x53 Space 0x20 0 0x30 1 0x31 CR 0x0D Response Byte 1 Byte 2 0x2A CR 0...

Страница 23: ...p 0x70 c 0x63 Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 0x3A Input 1st digit 0x30 0x32 Input 2nd digit 0x30 0x39 CR 0x0D Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8...

Страница 24: ...t a certificate Accept the NTI certificate A Welcome Page will appear Figure 20 Web interface Welcome page Enter the Password Click on a link to the left to be prompted for a username and password Def...

Страница 25: ...le Figure 22 Administrator Menu Switch Page Figure 23 Web interface Switch page Administrative users will have full access to the Switch page above which displays the active connections shown in orang...

Страница 26: ...on the selections made by the Set all Outputs to Input will take precedence when the Submit button is pressed Selections that conflict with it will be ignored For the Administrator Only To save a conf...

Страница 27: ...inactive web connection will stay logged in Any change to the Website Timeout configuration takes effect immediately The Telnet configuration block enables the VEEMUX to receive commands on port 2005...

Страница 28: ...user account and password can be logged into from more than one location Note The more users that are logged in the slower the VEEMUX will respond to changes in its settings Add User To add a user se...

Страница 29: ...ER MANAGEMENT section of the menu Figure 28 Edit User settings From the Edit User page the Administrator can change all user settings or delete the user altogether Just as Submit Full Access quickly p...

Страница 30: ...nges to input ports without pressing the port s respective Save button will be discarded All input port names must be no more than 12 characters in length and only alphanumeric characters may be used...

Страница 31: ...ount of time that each will be viewed 0 255 seconds can be set to cycle sequentially for each connected output If an input is set to 0 seconds the sequence status will display OFF and the input will b...

Страница 32: ...ge browse to the firmware file 3 Press Update Firmware 4 Wait for the following message to appear may take several minutes Upload Succeeded Flash of new image completed The system will automatically r...

Страница 33: ...e password must be between 5 and 16 characters in length and can be alphabetical or numeric Help Page This page explains the purpose of each of the other pages in the VEEMUX web interface Update Web S...

Страница 34: ...age This page will enable the user to end the session and close the web interface connection Click on the Press Here to Continue Logout button to exit the VEEMUX web interface Note The connection will...

Страница 35: ...d will be displayed Tip If your Windows program asks which program to open the NTIDiscover jar file with select the Java program Figure 36 Device Discovery Tool Click on the Detect NTI Devices button...

Страница 36: ...signals are listed below including equivalent CCITT V 24 identification and signal direction DB9F pin Common name EIA name CCITT name Function Direction 1 DCD CF 109 Not used 2 TxD BA 103 Transmit Da...

Страница 37: ...inated by the customer PROBLEM SOLUTION Telnet or webserver not working Check indicator LEDs on the back of the unit Is there a valid connection If not check all cable connections Does the data light...

Страница 38: ...ting temperature 10 C to 40 C Video quality adjustment Automatic up to 600 feet Replaceable fuse rating 2A 250V Power requirements 110 or 220VAC 50 or 60Hz 1A Appendix C Distances and Resolutions for...

Страница 39: ...for cables Figure 38 Mount Switch to a Rack Grounding These products have protective earth ground terminals and are built with full attention to consumer safety There must be an un interruptible safe...

Страница 40: ...quences 27 serial cables 32 Setup pages 23 Software control 17 speakers 4 Switch page 21 Telnet Interface 16 Telnet Interface Port 2005 17 Troubleshooting 33 Update Firmware 28 User management 24 user...

Отзывы: