background image

                   

MAN039 Rev 10/22/13 

                 

 
 
 

 

UNIMUX-USBV-xHD  

 High Density USB KVM Switch 

Installation and Operation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIMUX

TM

Series

 

Содержание UNIMUX-USBV-16HDU

Страница 1: ...MAN039 Rev 10 22 13 UNIMUX USBV xHD High Density USB KVM Switch Installation and Operation Manual UNIMUXTM Series...

Страница 2: ...thout reservation and without notification to its users FIRMWARE VERSION Main Controller Firmware Version 1 18 Typographic Conventions Typeface meaning Font Configuration Example On screen computer ou...

Страница 3: ...nt Panel Control 14 Keyboard Control 14 OSD CONTROL 15 Guidelines for Navigating OSD Menus 15 Security Option 15 Initial startup 16 User Access Functions 16 Command Mode 16 Settings 18 OSD Settings 19...

Страница 4: ...ions 38 Matrix Operations 38 Setup Options 38 RMTEST RS232 Interface Test Program 39 TELNET INTERFACE 40 Command Summary 40 Command Detail 41 RU Read Unit Size 41 RO Read Connection for Output Port 41...

Страница 5: ...e for RS232 control 9 Figure 9 Connect LAN to Ethernet port 10 Figure 10 Connect CAT5 cable for remote user 10 Figure 11 Connect monitor and devices to ST C5USBV R 300 11 Figure 12 CAT5 Enable Disable...

Страница 6: ...et port names 29 Figure 40 Select Language menu 29 Figure 41 Security Configuration 30 Figure 42 Login screen with security disabled 30 Figure 43 Adjust Baud Rate 31 Figure 44 Adjust Serial Address 31...

Страница 7: ...orded and wireless iKey combo keyboard and touchpad Types of CPUs Supported Any USB CPU supporting USB version 1 0 or above including USB Windows all USB MAC USB SUN Linux Other Devices Supported Touc...

Страница 8: ...the length of the cable in feet 3 6 10 or 15 feet available MM indicates male to male connector Required for models with Remote User support via CAT5 CAT5 5e 6 unshielded twisted pair cable s termina...

Страница 9: ...evice cables 7 USB Device Symbol USB Type A female connector for USB cable from touch screen monitor or CAC card reader models with extra USB device support only 8 MONITOR 15HD female connectors for c...

Страница 10: ...dedicated to each CPU preventing connected CPUs from locking up Any user device cable can be hot plugged The front panel LEDs indicate the CPU the user is connected to No dip switches or jumpers neces...

Страница 11: ...readed holes in the sides of the NTI switch Tighten the screws securely Figure 1 Secure rackmount ears to switch 2 Install 4 captive nuts not provided to the rack in locations that line up with the ho...

Страница 12: ...een support only connect the USB cable from the monitor to any one of the USB type A connectors in the same user device port group see Figure 4 Figure 3 Install user monitor Figure 4 Install user touc...

Страница 13: ...USB2 AA 5M USB 2 0 Active Extensions see Figure 6 purchased separately Contact your NTI salesperson for more details by calling 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http...

Страница 14: ...nnect each CPU using a HDUSBVEXT xx MM cable Figure 8 Models without video support connect using a HDUSB xx MM cable 250V 2A 12 4 11 3 10 2 9 1 CPU CPU 16 8 15 7 14 6 13 5 CPU CPU NETWORK TECHNOLOGIES...

Страница 15: ...security option is not enabled the monitor will display the desktop image for the connected CPU and the user can continue with normal operation of the connected CPU RS232 Connection If RS232 control w...

Страница 16: ...tor cable the keyboard and mouse and the AC adapter power connector can each reach the ST C5USBV R 300 comfortably 2 Connect the monitor cable to the 15HD female VIDEO port on the ST C5USBV R 300 See...

Страница 17: ...utton on the front of the UNIMUX so that the CAT5 option will be enabled The green Enable LED should flash indicating proper communication with the Remote Unit Figure 13 CAT5 Enable Disable button and...

Страница 18: ...Reader Connection If the UNIMUX you have purchased includes the extra USB port option UNIMUX USBV xHDU then it supports the connection of a CAC card reader When used the CAC card reader will connect t...

Страница 19: ...A maximum of 5 input devices may be connected to the UNIMUX either directly or through hubs See Figure 16 for some examples of input device combinations that can be used with the UNIMUX Figure 16 Comp...

Страница 20: ...ch switch on the front panel of the UNIMUX will connect the corresponding CPU to the monitor and input devices Holding down any front panel touch switch for more than 2 seconds will cause the UNIMUX t...

Страница 21: ...light for menu functions cyan or light blue for CPUs The scroll bar can be used by clicking on the corresponding up and down arrow above and below the scroll bar The mouse wheel may be used to move th...

Страница 22: ...At this point the Command Mode menu will be displayed The Command Mode menu see Figure 17 lists all CPUs by name and port number Only 8 ports are listed on the screen at a time To view the other porti...

Страница 23: ...de of control after entering into Command Mode Function Keystroke Select the previous port up arrow Select the next port down arrow Go to specific port Press any valid number from 1 1024 to connect to...

Страница 24: ...ettings menu functions available from the keyboard Function Keystroke Open OSD Settings screen O Go to Broadcast list B Go to Scan list S Change the scan dwell time period Enter any value from 002 255...

Страница 25: ...s screen Find Mode Find Mode is enabled by typing any alphabetical or numeric characters while in the Command Mode main menu or by pressing F while in supporting menus Find Mode allows the user to ent...

Страница 26: ...he Ctrl S keys are pressed When Scan Y is shown Scan Mode is active When Scan N is shown Scan Mode is OFF From the Settings menu see page 18 press S to access the Scan List The Scan List enables the u...

Страница 27: ...more computers simultaneously From the Settings menu see page 18 press B to access the Broadcast List where the user can edit the list of ports that receive data in Broadcast Mode The Broadcast List i...

Страница 28: ...id login the user will be connected to the first CPU that is powered ON To enter Command Mode press Ctrl accent tilde key The OSD menu will automatically appear on the monitor Figure 26 Administrator...

Страница 29: ...as determined by the administrator Note If security is not enabled the message Press F1 to Autologin will appear in the login screen While security is disabled a standard user must press F1 see Figur...

Страница 30: ...n MAC CPUs If the port will have a MAC CPU connected use the mouse to click on the box associated with the port to place a check mark in the box Note If a port is configured as connected to a non MAC...

Страница 31: ...g it to be edited If no name is entered a default name userXX where XX is the user number will be entered N Open an edit field to insert a user password up to 15 characters in length If no characters...

Страница 32: ...Exit and return to previous menu Changes made will be saved automatically Esc Figure 33 Access Control list Change Administrator Password To change the Administrator Password press C from the Administ...

Страница 33: ...UNIMUX for controlling the switch via Telnet Interface page 40 press E from the Administration menu The default values are shown in Figure 36 Function Keystroke Change the IP Address I Change the Subn...

Страница 34: ...38 2 enter the desired value 000 255 minutes 3 press Enter to save it and move to the next field 4 press Esc to exit the System Configuration menu Figure 38 Change the value of OSD Blank Timeout Alter...

Страница 35: ...at boot up For other types of CPUs this feature may have no effect A list of available languages is displayed and can be scrolled using the mouse scroll wheel and or up arrow down arrow Home and End k...

Страница 36: ...hrough U Enable Global Security security enabled on all user ports E Disable Global Security security disabled on all user ports D Return to previous menu Esc Figure 42 Security Configuration If Secur...

Страница 37: ...ss the Left arrow or Right arrow to change the value of the baud rate Note The baud rate can also be changed from the RS232 Command Protocol see page 34 For more on RS232 Control see page 34 Figure 44...

Страница 38: ...2 Compose R Alt R Alt R Option Alt Graph SB Alt Windows Logo Command Meta SB R Arrow SB R Arrow Power Suspend SB Space Bar L and R Left and Right keys when two keys are marked the same on a keyboard M...

Страница 39: ...lt Command Key Enter Enter Ctrl Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock Alt F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Scroll Lock Pause Break Print Screen SysRq Application Key Windows...

Страница 40: ...Transmit data RXD at host 7 No connection 8 No connection NOTE Security must be disabled or user access granted on the port s to be selected by RS232 control A 5 foot patch cable and two adapters RJ4...

Страница 41: ...Unit 2 9D Female 9D Male 9D Male Wiring Schematic of Matrix Y 1 cable NTI SWITCH CPU RS232 First Unit NTI SWITCH RS232 NTI SWITCH RS232 Second Unit Last Unit RS232 Serial Port Matrix Y 1 Matrix Y 1 M...

Страница 42: ...w GM SW 00 CR go SW OP IP CR all connections List all switch User port connections all User ports to all CPU ports RP SW IP CR Refresh Communication with CPU USB port If the first field is not a known...

Страница 43: ...rful graphical program that controls NTI KVM switches through an RS232 interface The NTI Switch Control Program is included on the CD packaged with the UNIMUX The NTI Switch Control Program is downloa...

Страница 44: ...y save the connections into switch memory bank b Restore I O Connections from Unit Memory restore the connections from switch memory bank c Change All Units Baud Rate 9600 COM1 change RS232 Baud rate...

Страница 45: ...onnect an input to all outputs 5 Read single output read which input is connected to an output 6 Read unit size read how many inputs and outputs the unit has 7 Return to main menu go back to the MAIN...

Страница 46: ...MUX Legend All numbers must be two digits OP Output Port 01 IP Input Port 01 MAXINPUTS CR Carriage Return Hex 0xD NN Connection configuration reference number 00 99 Command Summary Command String Good...

Страница 47: ...4 Byte 5 Byte 6 R 0x52 O 0x4F Space 0x20 Output 1st digit 0x30 0x32 Output 2nd digit 0x30 0x39 CR 0x0D Response Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9 p 0x70 c 0x63 Space 0x20...

Страница 48: ...and this command must be entered to enable it When auto status mode is enabled a message will be sent whenever an input output connection changes from any source The format of this message is given in...

Страница 49: ...Byte 1 Byte 2 0x2A CR 0x0D CC Save connection configuration into permanent memory at given location Command Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 C 0x43 C 0x43 Space 0x20 Location 1st digit 0x30...

Страница 50: ...x0D Response Byte 1 Byte 2 0x2A CR 0x0D This command will refresh the USB communication with the CPU in cases where the USB port will be put in standby by the operating system Terminate telnet session...

Страница 51: ...e to the frequency characteristics of the CAT5 cable It may be necessary to enter Command Mode described above and press the up arrow or down arrow keys on the remote keyboard until the image is crisp...

Страница 52: ...Specific Port Controller there is one such controller for each CPU port available on the switch it will be upgraded with an Intel hex file named unimux suhd cpvdx x hex Each CPU port is upgraded inde...

Страница 53: ...g settings to the terminal console for the port connected to the UNIMUX Baud rate 57600 Data bits 8 Parity none Stop bits 1 Flow control none 250V 2A 12 4 11 3 10 2 9 1 CPU CPU 16 8 15 7 14 6 13 5 CPU...

Страница 54: ...or commands The available commands are composed by sending one ASCII character To send a command to the bootloader type the key in the terminal window that corresponds to the desired command The avail...

Страница 55: ...tart shortly Wait until the transmission is finished There will be some pauses during transmission since the processor writes blocks of 4KB When the transmission is complete the HyperTerminal window s...

Страница 56: ...age above will be repeated for each port that was programmed After all are programmed unless the switch has 32 CPU ports the following message will be shown on the screen Programming device please wai...

Страница 57: ...the checksum type s for HID port controllers or t for vendor specific port controllers at the bootloader prompt The following message will be displayed Please type the two digit number of the port to...

Страница 58: ...LES NTI DESCRIPTION HDUSBVEXT 3 6 10 15 MM Connect each CPU to the UNIMUX UHD with one USBVEXT 3 6 10 VGA and USB extension USBVEXT 3 6 10 15 MM VGA and USB interface USB AA 5M Connect up to 5 cables...

Страница 59: ...V Extender Driver communication not correct between mouse and CPU Port set for non MAC mode Configure any CPU ports that have a ST C5USBV connected for MAC Mode operation see page 24 Mouse not working...

Страница 60: ...ng 5 remote user 45 reset port names 29 31 RMTEST 39 RS232 Command Protocol 36 RS232 pinout 34 Scan Mode 20 security configuration 30 security enable 30 Security features 15 Select Language 29 SerTest...