RACKMUX-T15 

                            Rack Mount ANSI 

                           Terminal Drawer 

 

                                    Quick Start Setup Guide

 

 
Introduction 

The RACKMUX-T15 (RACKMUX) is a general-purpose character terminal with a 15" color LCD display and keyboard mounted in 
a 1U high rack mountable tray. The RACKMUX connects to servers using either a serial RS232 console connection or an Ethernet 
telnet RSC console connection (to the RSC Ethernet console port where available).  The terminal offers multiple personalities, and 
can connect to multiple servers when used with a Console Server (for RS232 connections) or with an Ethernet Switch (for 
Ethernet connections).  This guide describes the basic installations and configuration procedure. For further details, please see 
the RACKMUX-TERMINAL Installation and Operation Manual.  

 

 

Hardware Installation 

Hardware installation consists of the following steps: 
 
1. Determine the mounting height in the rack for the drawer.    It should be a height comfortable to use the keyboard and see the 
LCD display.  Mark holes in each of the 4 corner cabinet rails at points all level with each other.   
 
2. Secure the rear brackets to the rear rack cabinet rails at the holes marked in step 1 using #10-32x3/4” screws and cage nuts 
(supplied).   Be sure to tighten the screws securely.     
 
3. Lift the keyboard into position and line the studs on the left and right sides up with the slotted openings in the rear bracket.   
Apply the nuts (supplied) to the studs but do not tighten the nuts yet.  
 

FYI:  There are 5 mounting studs provided on each side of the RACKMUX.  Depending on the depth of the rack and 
distance apart of the cabinet rails, the position of the rear bracket may make all 5 studs available for use.    In this case, 
apply the 2 nuts to the studs furthest apart from each other on each side.   

 
4.  Slide the drawer in until the top holes in the front bracket flanges line up with the holes marked in step 1.   Secure the front 
brackets on the drawer to the front cabinet rails using #10-32x3/4” screws and cage nuts (supplied).   Be sure to tighten the 
screws securely.    Then tighten the nuts applied in step 3.  

               

Note: Very deep racks may require the back of the rails to be bolted to an internal mid-rail within the rack, in which 
case the rear rail extensions should be reversed so as to present the appropriate mounting holes to the rack mid-
rails. 

Man030  Rev 7/30/2007 

RACKMUX

®

 Series

 

Apply nuts (supplied) to studs and
secure rear brackets to drawer.

Front bracket
flange on drawer

Rear bracket

flange

Drawer

Front Cabinet

Rail

Rear Cabinet

Rail

Rear bracket overlapping
drawer

(Rear edge
of drawer)

Stud on drawer

Apply nuts (supplied) to studs and
secure rear brackets to drawer.

Front bracket
flange on drawer

Rear bracket

flange

Drawer

Front Cabinet

Rail

Rear Cabinet

Rail

Rear bracket overlapping
drawer

(Rear edge
of drawer)

Stud on drawer

Apply nuts (supplied) to studs and
secure rear brackets to drawer.

Front bracket
flange on drawer

Rear bracket

flange

Drawer

Front Cabinet

Rail

Rear Cabinet

Rail

Rear bracket overlapping
drawer

(Rear edge
of drawer)

Stud on drawer

Apply nuts (supplied) to studs and
secure rear brackets to drawer.

Front bracket
flange on drawer

Rear bracket

flange

Drawer

Front Cabinet

Rail

Secure bracket
to rail using two

screws and nuts

(supplied)

Rear Cabinet

Rail

Rear bracket overlapping
drawer

(Rear edge
of drawer)

Stud on drawer

Secure bracket
to rail using two

screws and nuts

(supplied)

NETWORK
TECHNOLOGIES
INCORPORATED

Tel:330-562-7070
Fax:330-562-1999

1275 Danner Dr
Aurora, OH 44202

  www.networktechinc.com