Страница 1: ...MAN202 Rev Date 05 13 2013 PRIMUX RDSW PRIMUX Redundancy Switch Installation and Operation Manual PRIMUX Series...

Страница 2: ...ner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the produc...

Страница 3: ...Power Up Sequence 6 Power LEDs 7 Connection Control Switch 7 Technical Specifications 8 Interconnection Cable wiring Method 8 TABLE OF FIGURES Figure 1 Connect User Stations 4 Figure 2 Connect Host Ad...

Страница 4: ...onnecting up to 16 users connected through PRIMUX UZR User Stations to up to 64 servers connected through PRIMUX Host Adapters HA UNV HA SUN and or HA RS Quickly switch control of User Stations and Se...

Страница 5: ...r HA SUN Legacy SUN Host Adapter HA RS M Serial Host Adapter CAT5 5e 6 shielded twisted pair cable s terminated with RJ45 connectors wired straight thru pin 1 to pin 1 etc see pg 8 for proper EIA TIA...

Страница 6: ...and Matrix Switch B 3 Switch x x 1 or 2 Rocker Switch used to switch power On Off from the power source 4 F1 F2 Fuse Holder for replaceable overcurrent 2A 240VAC Fast blo protection fuse 5 AC Input x...

Страница 7: ...e same number USER port on the PRIMUX RDSW with an A added 1A 2A 3A etc This will be PRIMUX Matrix Switch A Note For best performance use CAT5e STP cables to connect the PRIMUX Matrix Switch to the PR...

Страница 8: ...IMUX Matrix switch A to the same number CPU port on the PRIMUX RDSW with an A added 1A 2A 3A etc Note For best performance use CAT5e STP cables to connect the PRIMUX Matrix Switch to the PRIMUX Redund...

Страница 9: ...o each User Station 2 Power ON each User Station 3 Power ON the PRIMUX RDSW 4 Press the Connection Control Switch on the PRIMUX RDSW towards the position of the desired connected PRIMUX Matrix Switch...

Страница 10: ...owards A all users and CPUs are connected through PRIMUX Matrix Switch A All common port numbers x are connected to Switch A ports xA When the switch is toggled towards B connections are through PRIMU...

Страница 11: ...5 5e 6 Solid STP EIA TIA 568 B wiring w male RJ45 connectors Host Adapter Compatibility HA UNV HA SUN HA RS M Size In WxDxH 19 x 12 125 x 6 940 Fuse protection 2A 240VAC 5x20 mm Slo blo Power requirem...