Appendix C - Regulatory Information
Power Cord Selection
156
Power Cord Selection
■
This enclosure is intended for indoor use only.
■
This enclosure is intended to be plugged into a 6A branch circuit in
Europe.
■
To select the proper power cord:
For 110 Volt Operation – Use a UL Listed/CSA Labeled cord set consisting of
a minimum 18 AWG, type SVT or SJT three conductor cord, terminating in a
molded connector body having an IEC CEE-22 female configuration on one
end and a molded-on parallel blade grounding type attachment plug rated
15A, 125V configuration (5 - 15P) at the other end.
For 230 Volt Operation (North America) – Use a UL Listed/CSA Labeled cord
set consisting of a minimum 18 AWG, type SVT or SJT three conductor cord,
terminating in a molded connector body having an IEC CEE-22 female
configuration on one end and a molded-on tandem blade grounding type
attachment plug rated 15A, 250V configuration (6 - 15P) at the other end.
For 230 Volt Operation (Europe) – Use a cord set marked “HAR”, consisting
of a H05VV-F cord that has a minimum 0.75 square mm diameter conductors
provided with an IEC 320 receptacle and a male plug for the country of
installation rated 6A, 250V.
NOTE:
The enclosure automatically selects the proper settings for the input
voltage. Therefore, no additional adjustments are necessary to connect the
unit to any input voltage within the range marked on the drive.
■
Das Laufwerk sollte nicht im Freien verwendet werden.
■
In Europa, sollte das Laufwerk an einen 6A-Stromkreis angeschlossen
werden.
■
Zur Wahl des korrekten Netzkabels beachten Sie bitte folgendes:
230V-Betrieb (Europa) – Verwenden Sie Netzkabel der Bezeichnung “HAR”
die H05VV-F-Kabel und einen Leitungsdurchmesser von mindestens 0,75
mm2 aufweisen. Verwenden Sie eine IEC 320-Buchse und einen für das
Installationsland passenden Stecker, der auf 6A und 250V gesichert ist.
4200F.book Page 156 Thursday, January 23, 2003 2:47 PM
Содержание NexStor 4200F Series
Страница 2: ...4200F book Page 2 Thursday January 23 2003 2 47 PM...
Страница 8: ...Table of Contents iv 4200F book Page iv Thursday January 23 2003 2 47 PM...
Страница 12: ...About this Manual Features viii 4200F book Page viii Thursday January 23 2003 2 47 PM...
Страница 32: ...Chapter 1 Getting Started Audible Alarm 20 4200F book Page 20 Thursday January 23 2003 2 47 PM...
Страница 156: ...Chapter 6 Maintenance Replacing the Enclosure 144 4200F book Page 144 Thursday January 23 2003 2 47 PM...
Страница 160: ...Appendix A Technical Information Specifications 148 4200F book Page 148 Thursday January 23 2003 2 47 PM...
Страница 172: ...Index 160 4200F book Page 160 Thursday January 23 2003 2 47 PM...
Страница 173: ...4200F book Page 161 Thursday January 23 2003 2 47 PM...