General Information 

 

This manual contains information regarding the installation and safe handling of NSP photovoltaic (PV) 
modules. All instructions should be read and understood before attempting to install. If there are any 
questions, please contact your dealer or NSP for further information. The installer should conform to all 
safety precautions in the manual when installing modules. Before installing a PV system, the installer should 

become familiar with mechanical and electrical requirement for the PV system. All installations must be 
performed in compliance with all applicable regional and local codes or other national and international 
electrical standards. Keep this manual in a safe place for future reference. 

 

Safety Precaution for Installing Solar PV System

 

 

-

 

NSP  modules  are  qualified  for  Application  Class  A:  Hazardous  voltage  (greater  than  50  V  DC)  or 
hazardous  power  applications  (greater  than  240  W),  where  general  contact  access  is  anticipated. 
Modules  qualified  for  safety  under  IEC  61730-1,  IEC  61730-2  and  within  this  application  class  are 
considered to meet the requirements for Safety Class II. 

-

 

Installing PV systems should be performed only by qualified or licensed experts. 

-

 

Ensure  that  the  NSP  modules  are  fastened  to  proper  mounting  systems  designed  for  appropriate 
mechanical loads resulting from wind and snow, and the proper weight of the modules. 

-

 

It is suggested that completely cover the module with an opaque material during installation to keep 
electricity from being generated. 

-

 

Be very careful when disconnecting wires connected to PV modules that are exposed to sunlight, an 
electric arc may result. Such arcs may cause burns, may start fires and may create problems. 

-

 

Artificially concentrated sunlight shall not be directed on the module or panel. 

-

 

Use only insulated tools that are approved for working on electrical installations. 

-

 

Routine maintenance of module    shall not involve breaking or disturbing the bonding path. 

-

 

All  of  installation  and  handling  activities  must  be  carried  out  with  due  care,  all  collisions  must  be 
avoided. 

-

 

Lift  pallets  by  a  fork  lifter  by  a  minimum  of  70%  of  pallet  length  when  loading  and  unloading  from  the 
length  side  of  a  pallet;  and  100%  of  pallet  width  when  loading  and  unloading  from  the  width  side  of  a 
pallet.

 

-

 

Do not attempt to disassemble the module or remove any part of module. 

-

 

Do not remove the attached nameplate or components. 

-

 

Do not stand or walk on modules. Otherwise it will result in unexpected no matter   
permanent or impermanent module defects, such as cracks, snail trails and etc.   

Please read this manual carefully before installing the modules. 
Non-compliance with these instructions may void the modules 
warranty. 
 

Содержание D6M A1A

Страница 1: ...ters 7 Li Hsin 3rd Rd Hsinchu Science Park Hsinchu 30078 Twain Tel 886 3 578 0011 Fax 886 3 578 1255 E mail Sales module nsp com INSTALLATION MANUAL D6M_BxA Series D6M_B1A D6M_B2A D6M_B3A D6M_B5A D6M_...

Страница 2: ...2 Content General information Safety precaution for the installing solar PV system Fire safety Mechanical installation Electrical installation Commission Maintenance Disclaimer of Liability 2 2 3 4 9...

Страница 3: ...proper mounting systems designed for appropriate mechanical loads resulting from wind and snow and the proper weight of the modules It is suggested that completely cover the module with an opaque mat...

Страница 4: ...25 percent 80 percent de rating which may be applicable Fire Safety NSP modules are rated as Fire Class C according to UL 790 Standard To use components such as earth ground fault circuit breakers fus...

Страница 5: ...eel made unless otherwise specified it should use corrosion proof fixing material The module mounting structure must be made of durable corrosion resistant and UV resistant material There are two appr...

Страница 6: ...modules can be mounted by using clamps Clamp A and Clamp B which is designed for solar modules as shown in Fig 2 1 Modules must be mounted at 4 symmetrical points by the means shown in Fig 2 2 and Fi...

Страница 7: ...g components must be corrosion proof material The applied torque is about 8 N m The modules are supported parallel to surface of the building wall or roof Sufficient clearance recommended is 140 mm be...

Страница 8: ...lamping at Module Short Side Frame Module Series Module Dimension Acceptable Clamping Range W 4 D6M_B1A D6P_B1A 1015 x 992 x 40 mm 248 mm D6M_B2A D6P_B2A 1330 x 992 x 40 mm 248 mm D6M_B3A D6P_B3A 1640...

Страница 9: ...8 Ver 0 2 Clamping at Module Long Side Frame Illustration Load 2400 Pa Load 5400 Pa...

Страница 10: ...rting surface or frame Electrically ground the frame of the module or array to avoid the hazards of electric shock and fire Bonding shall be by a positive means such as clamping riveting bolted or scr...

Страница 11: ...f fixing material as shown in Fig 3 2 The grounding wire should not be smaller than 12 AWG The grounding wire should be 2 meters in length multi conductor and rated of 105 C and 600V Recommended torqu...

Страница 12: ...use tin plated solid copper lay in lug with a stainless steel set screw capable of accepting a 4 12 AWG copper conductor e g ILSCO GBL 4DBT Burndy CL50 1TN Length of bolts should not be more than 20m...

Страница 13: ...dule Illustration B as below shows 4 modules connected in parallel If modules are connected in parallel the total current is equal to the sum of individual module current Connecting modules in paralle...

Страница 14: ...We recommend that all wiring and electrical connections comply with the National Electrical Code NEC For field connections use the solar cable with appropriate cross section according to TUV 2 PfG 11...

Страница 15: ...ns regulatory to verify they are clean secure and undamaged Disclaimer of Liability The use of this manual the installation conditions or methods operation use and maintenance of PV modules are beyond...

Отзывы: