Model FMP
100 -
200 PROOFER
Страница 1: ...Model FMP 100 200 PROOFER ...
Страница 2: ......
Страница 3: ...NUAL Table of contents PAGE 1 Installation 1 2 Safety information 3 3 Features Controls 4 4 Operating instructions 5 5 Technical 7 Parts Electrical 9 Schematic 10 Friedrich Metal Products Co Inc 6204 Technology Drive Browns Summit NC 27214 336 375 3067 ...
Страница 4: ...h plans and specifications provided by Friedrich Contact FMP in writing FAX 336 621 7901 for resolution of any matter arising out of interpretation of plans and or specifications o Further if installers determine that an installation cannot be accomplished in strict accordance with plans and specifications the customer must contact FMP in writing FAX to request a written authorization FAX to devia...
Страница 5: ...ity problems contact a local water treatment company for recommended filter softener installations 2 2 INSTALLATION DIAGRAMS Figure 4 1 and 4 2 show where electrical service and plumbing facilities are to be connected to a Proofer being installed The electrical lines shall be run and connected in strict compliance with local codes for 120 volt ac and 208 240 volt ac service The plumbing shall also...
Страница 6: ...r and free of combustible materials gasolines and other flammable vapors and liquids 4 DO NOT open service panel when unit is in operation or leave open during operation 5 DO NOT allow unqualified personnel to perform service work or adjustments on this unit To do so will VOID warranty and could result in a hazardous condition 6 Be sure any new employees who might operate the unit are instructed o...
Страница 7: ...ofer to set value Extinguishes when set value is o btained 3 POWER SWITCH To be set to On position for proofing Built in power indicator lights to show 120 volt AC power is applied to the blower and or contro l circuit 4 HUMIDITY CONTROL To be set between 60 and 70 RH depending on local conditions and product to be proofed 5 HUMIDITY INDICATOR Light to show system is operating to bring humidity in...
Страница 8: ...tween 90 and 110 degrees F Observe that temperature indicator lights up showing that system is operating to bring temperature in proofer to set value STEP 3 Wait 20 30 minutes for humidity and temperature inside proofer to stabilize NOTES 1 If humidity is set too high condensation inside proofer may be excessive and water will accumulate on floor 2 Frozen dough products must be completely thawed b...
Страница 9: ...lation diagrams also give details of the physical features of each Proofer model for use by installation planners and installers These physical features include dimensional data uncrated weights and clearances required for running and connecting electrical and plumbing lines Use the installation diagram for the Proofer model as a guide to installing the unit 6 ...
Страница 10: ...EIGHT 450 LBS UNIT REQUIRES A FLAT AND LEVEL FLOOR DOOR OPENING 23 X 75 BAKERY PROOFER MODEL FMP 200 909 2 7 8 O FOR 110V ELECTRIC SERVICE 7 8 O FOR 220V ELECTRIC SERVICE 1 4 NPT WATER SUPPLY HI TEMP LIMIT RESET 3 4 NPT DRAIN 23 180 CLEAR DOOR 23 180 CLEAR DOOR 37 314 31 428 CLEAR INSIDE 7 ...
Страница 11: ...8 2008 7 2 2012 910 PROOFER ASSEMBLY 910 1000 ASSEMBLY dft FMP 910 PROOFER GB NS A 45 500 42 883 CLEAR INSIDE 32 000 29 000 CLEAR INSIDE 75 0 CLEAR INSIDE 47 085 1 2 NPT DRAIN HI TEMP LIMIT RESET 1 4 NPT WATER SUPPLY 45 PSI MIN 7 8 O FOR 220V ELECTRIC SERVICE 7 8 O FOR 110V ELECTRIC SERVICE BAKERY PROOFER MODEL FMP 200 910 POWER REQUIREMENTS 120V 1 PH 15 AMP 240V 1 PH 15 AMP WEIGHT 450 LBS UNIT RE...
Страница 12: ... 1 3 LIGHT INDICATOR TEMPERATURE 1 4 CONTROL HUMIDITY 1 5 LIGHT INDICATOR HUMIDITY 1 6 HIGH TEMPERATURE LIMIT MANUAL RESET 1 7 TERMINAL BLOCK 120 VOLT 1 8 TERMINAL BLOCK 240 VOLT 1 9 GROUNDING LUG 1 10 VALVE HUMIDITY 1 11 RELAY HEAT 1 12 HEATER 1 13 BLOWER 1 PROOFER TEMPERATURE HUMIDITY POWER 5 3 4 2 1 6 7 8 9 10 11 12 4 5 1 2 13 3 9 ...
Страница 13: ...R SWITCH TEMP IND LIGHT HUMIDITY IND LIGHT TEMP CONTROL HIGH TEMP LIMIT S N C BLOWER S DRAWN 03 24 11 Drawing 1 FMP 100 FMP 200 Electrical Schematic METAL PRODUCTS Proofer DWG 100 1 SERIAL NO 022 Rev C L 120 V 1 phase 15 amp 240V 1 phase FMP 100 200 15 amp Relay FIG 5 1 G Ground 7 8 120 V 10 ...