32
National Rejectors, Inc. GmbH, Buxtehude
M
AINTENANCE
AND
SERVICE
Troubleshooting
Malfunctions can occur in all electromechanic devices. These do not always
have to be faults in the device. In many cases the reason is improper
connections or incorrect settings. Therefore: please first of all check,
whether the malfunction can simply be remedied using the following table.
Problem
Yellow LED
flashing
Red LED
flashing
1x
2x
3x
6x
Possible causes
Hopper is paying out a
coin
Hopper error
Coin payout sensor
(after switch-on)
• covered by coin
permanently
• contaminated
• defective
Coin payout, although
motor has not been
activated by control
system
• Coin jam although
rotational direction
has been changed
several times (40 x)
(anti-jam function)
• Hopper empty:
Although rotational
direction has been
changed 8 times, no
coin has been paid
out
Error, coin payout
sensor
Remedy, hints
No error
• Eliminate coin jam
• Clean sensor (see section "Cleaning
hopper" in this chapter)
• Replace sensor (service case)
Prevent manipulation
• Eliminate coin jam
• Refill hopper
• Clean sensor (see section "Cleaning
hopper" in this chapter)
• Check connection (service case)
• Replace sensor (service case)
Содержание Currenza H2 Hopper Series
Страница 2: ......
Страница 6: ......
Страница 41: ...41 National Rejectors Inc GmbH Buxtehude TECHNICALDATA Top view Mounting dimensions h2 S View from the side ...
Страница 42: ...42 National Rejectors Inc GmbH Buxtehude TECHNICALDATA h2 M View from the side Top view ...
Страница 43: ...43 National Rejectors Inc GmbH Buxtehude TECHNICALDATA h2 L View from the side Top view ...