![NRG Systems HXT Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/nrg-systems/hxt/hxt_product-manual_1714011006.webp)
NRG Product Manual
Hybrid XT Anemometer
HybridXT_Anemometer_Manual
Rev. 15
[email protected] | Page 6
02 January 2020
ANEMOMETER OPERATION AND CONSIDERATIONS
The HXT anemometer is available with a variety of output signal types including variable frequency and
4-20mA, among others.
Hybrid XT Anemometer Types
Sensor
Part #
Output
Signal
Meas.
Range
Scaling
Notes
#4718
Frequency
(Hz)
0-50 m/s
1-101 Hz
m/s = 0.5(Hz) – 0.5
0 Hz = sensor fault
High-level square wave output
Amplitude equals supply voltage
Compatible with Personality Module
(NRG Part #3798)
Recommended load resistance
1200 Ω minimum
#5763
mA
0-50 m/s
4-20 mA
Linear mA scaling
<4 mA = sensor fault
Standard 4-20 mA current loop
0.1 m/s resolution
Recommended load resistance
50 Ω–1000 Ω
#7901
Frequency
(Hz)
0-60 m/s
0-117 Hz
m/s = 0.509(Hz) +
0.4
High-level square wave output
Compatible with PNP & NPN inputs
Amplitude equals supply voltage
Output scaling matches NRG IceFree3
anemometer
Recommended load resistance
1200 Ω minimum
#9365
mA
0-60 m/s
4-20 mA
Linear mA scaling
<4 mA = sensor fault
Standard 4-20 mA current loop
0.1 m/s resolution
Recommended load resistance
50 Ω–1000 Ω
#9387
Frequency
(Hz)
0-60 m/s
0-105 Hz
m/s = 0.566(Hz) +
0.4
High-level square wave output
Compatible with PNP & NPN inputs
Amplitude equals supply voltage
Output scaling is 90% of #7901 HXT
Recommended load resistance
1200 Ω minimum