NRG Product Manual
Hybrid XT Anemometer
HybridXT_Anemometer_Manual
Rev. 15
[email protected] | Page 13
02 January 2020
HXT SENSOR INSTALLATION
Mounting Mast Orientation
Refer to the technical drawing for details on mounting mast design. Orient the cross-holes in the top of
the mounting mast such that they are lined up parallel to the turbine nacelle centerline.
Prepare Shield
Based on your decision about the cable shield connection scheme, cut off or attach the shield to the
mounting mast. If you choose to cut the shield wire, make sure to cut it off short enough to avoid
touching the mounting mast or bolt.
Cross-holes
Typical
mounting
mast
Nacelle centerline
Align cross-holes parallel to nacelle centerline.
If cutting shield wire, cut close to
connector base as shown.