SELF-PRIMING CENTRIFUGAL PUMPS

BMLS-M & BMLS-H

INSTALLATION, OPERATION & MAINTENANCE

INSTRUCTIONS

HP

Phase

Medium Head

  High Head

3

1

BMLS 300 M

BMLS 300 H

3

3

BMLS 300 M3

BMLS 300 H3

5

1

BMLS 500 M

BMLS 500 H

5

3

BMLS 500 M3

BMLS 500 H3

GENERAL INSTRUCTIONS

Examine unit for any visible shipping damage. Immediately
report any damage to the carrier.  Check all accessory parts
carefully against the invoice. All pipe used should be clean
and free from rust and scale. Use pipe joint compound on
all joints to avoid leaks.

INSTALLATION & OPERATION

Pump Location:

 Locate the pump as near the well or water

source as possible, using short, direct suction pipe. Keep
the static suction lift (vertical distance between the center
line of the pump and water level) to a minimum. Mount the
pump on a solid, level foundation, which provides a rigid

and vibration free support. It should be located where the
unit is readily accessible for service and maintenance. The
pump should be protected against flooding and excessive
moisture.

Piping:

 Both suction and discharge piping should be

independently supported at a point near the pump to avoid
strains being placed on the pump. Start all piping at pump to
avoid strains left by a gap at last connection. It is advisable
to increase the size of both suction and discharge piping at
the pump if any appreciable run of pipe is required. Never
use a smaller suction pipe than the suction connection on
the pump.