background image

 

 

 

Instruction Manual

 

of NF-583/586 Mobile 

Phone Infrared Thermal Imager 

Version (V1.0) 

 

 

 

 

Содержание NF-583

Страница 1: ...Instruction Manual of NF 583 586 Mobile Phone Infrared Thermal Imager Version V1 0 ...

Страница 2: ... 5 3 1 Setting 8 5 3 2 About 9 5 3 3 Interface Reset 10 5 3 4 Photo Taking 10 5 3 5 Video Recording 11 5 3 6 Album 12 5 3 7 Color palette 13 5 3 8 Regional Temperature Measurement 15 5 3 9 Temperature Tracking 15 5 3 10 Rectangle Temperature Measurement 16 5 3 11 High Temperature Alarm 17 5 3 12 Highlighted High temperature Regions 18 6 PRECAUTIONS FOR USE AND MAINTENANCE 19 7 PACKING LIST 20 8 AP...

Страница 3: ...l pixel spacing and high resolution ratio and is equipped with a 3 2mm lens The product is lightweight and portable and can be used directly when plugged in With the customized professional thermal image analysis APP it can be connected to a mobile phone to carry out infrared imaging of the target object making it possible to perform multi mode professional thermal image analysis anytime and anywh...

Страница 4: ...00 It supports high temperature alarm and customized alarm threshold It supports the display of user defined temperature range screen and has many use scenarios for the display of high temperature regions It supports high and low temperature tracking It supports adding points lines and rectangular boxes for regional temperature measurement with lines and rectangular boxes supporting high and low t...

Страница 5: ...0mK 25 Lens 3 2mm Temperature measurement range 15 600 Temperature measurement accuracy 2 Cor 2 of reading Temperature measurement Highest lowest central point and area temperature measurement are supported Color palette 6 General items Language English Working temperature 10 C 75 C Storage temperature 45 C 85 C IP rating IP54 Dimensions 34mm x 26 5mm x 15mm 19g Net weight ...

Страница 6: ...5 4 Appearance and Equipment Connection Hardware Appearance and Part Name ...

Страница 7: ...onnection is required to be enabled in the mobile phone settings to run the APP normally because its location varies from phone to phone you can search for OTG in the settings 5 2 Interface Introduction Connect NF 583 586 to an Android phone and run APP and you can see the interface as shown in Figure 5 1 Figure 5 1 0 1 Figure 5 1 0 1 ...

Страница 8: ...rent color palette can be switched to change the color of the video Regional Temperature Measurement Points lines and boxes can be added to measure temperature in different regions Temperature Tracking The current maximum temperature minimum temperature and center point temperature in the screen can be tracked Rectangle Temperature Measurement The current temperature in all rectangular boxes can b...

Страница 9: ...on Introduction 5 3 1 Setting Click the Settings button to pop up the settings panel as shown in Figure 5 2 Figure 5 2 0 2 See Table 2 for the description of each setting item in the panel Table 2 2 Figure 5 2 0 2 ...

Страница 10: ...get Humidity Parameter values shall be filled in according to the humidity of the test environment Correction Correction parameters shall be filled in according to the temperature measurement deviation Reflection temperature Parameter values shall be filled in according to the reflection temperature of the test environment Ambient temperature Parameter values shall be filled in according to the te...

Страница 11: ...ult state at startup Figure 5 4 0 4 5 3 4 Photo Taking Click the Photo Taking button to take the current infrared screen and save it automatically The photo button will remain red for one second and the heat map window will have an animation that is drawn into the album when the photo is successfully taken Figure 5 5 0 5 Figure 5 5 0 5 ...

Страница 12: ... When the Video Recording button is clicked the button will turn red accordingly and the recording time will be displayed correspondingly in the lower left corner of the video window at the same time Click the Video Recording button again to stop video recording Figure 5 6 0 6 ...

Страница 13: ...llery is shown in Figure 5 7 with all files arranged in chronological descending order Figure 5 7 0 7 Album Photos and video files are displayed at the same time Photo Only photo files are displayed Video Only video files are displayed with the video duration in the preview image Trash can Files are selected and then deleted ...

Страница 14: ...scenario where the high temperature region occupies the main proportion White heat The high temperature section adopts white and the full screen mainly adopts black and white transition which is suitable for users of black and white traditional mode Black heat The high temperature section adopts black and the full screen mainly adopts black and white transition which is suitable for users of black...

Страница 15: ...red and black and from the minimum temperature to the maximum temperature the black white and red transition mode is adopted which is suitable for scenarios focusing on the high temperature state Cold blue Blue is used to mark the colder regions which is more suitable for observing low temperature target objects By adjusting the color palette bar on the right side of the screen the temperature ran...

Страница 16: ...rature and minimum temperature of the region By long pressing each new region the trash can icon will pop up for deletion Figure 5 10 0 10 5 3 9 Temperature Tracking Click the temperature tracking button on the right to enable or disable the measurement of the maximum temperature minimum temperature and center point temperature in the real time screen Red is the maximum temperature blue is the min...

Страница 17: ...an be highlighted If there is no rectangular box in the current screen a rectangular box will be automatically added in the default position By long pressing the rectangular box its size can be adjusted and its position can be dragged and by clicking the delete icon next to it the rectangular box can be deleted ...

Страница 18: ...ue pops up on the interface as shown in the figure below When the maximum temperature value in the screen is higher than the alarm threshold value in the regional temperature measurement mode the temperature in the region is taken as the benchmark except point measurement the system will sound an alarm and the video screen will flash a red alarm Figure 5 13 0 10 ...

Страница 19: ... and the other regions are displayed as white heat and the temperature range can be adjusted by the slider on the right side of the color board bar The analysis mode of highlighted high temperature regions facilitates most application scenarios that focus solely on temperature values of high temperature regions Figure 5 14 0 11 ...

Страница 20: ...tergent and other organic cleaners to clean the lens It is recommended to wipe the lens with soft objects dipped in water 2 Do not let sunlight laser and other strong light sources directly illuminate the lens otherwise the thermal imager will suffer irreparable physical damage ...

Страница 21: ...20 7 Packing List Name Quantity NF 583 586 host 1 set Lens cleaning cloth 1 pcs Cloth bag 1 pcs Instruction manual 1 pcs ...

Страница 22: ... 75 to 0 80 Sand 0 9 Charcoal powder 0 96 Soil 0 92 to 0 96 Paint 0 80 to 0 95 Water 0 92 to 0 96 Paint matte 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Wood 0 9 Pottery 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxide 0 81 Plaster 0 80 to 0 90 Copper oxide 0 78 Mortar 0 89 to 0 91 Ferric oxide 0 78 to 0 82 Brick 0 93 to 0 96 Textile 0 9 ...

Отзывы: