1.

 

PRESENTATION 

N1500G  is  a  universal  process  indicator  which  accepts  a  large 
variety of input signals and sensors. A five-digit  LED display shows 
measured value and all programming parameters. 

Instrument configuration is achieved from the keyboard, without any 
hardware change. 

The  user  should  read  this  manual  thoroughly  before  using  the 
instrument.  It  is  a  fine  electronic  device  and  should  be  used 
accordingly for best results. 

Some of the features of the basic version are: 

 

Universal input: Pt100, thermocouples, 4-20 mA, 0-50 mV and 0-5 
Vdc 

 

24 Vdc power supply for remote transmitters excitation 

 

Maximum

 and 

minimum 

memory 

 

Function

 Hold, Peak hold 

and

 Tare

 

Optionally may have: 

 

Process Variable retransmission in 0-20 mA or 4-20 mA 

 

RS485 MODBUS RTU serial communication 

 

Stabilized 10 V supply to feed load cell 

 

Digital input 

1.1.

 

FRONT PANEL IDENTIFICATION 

Display

:  Shows  process  variable  (PV)  and  the  programming 

prompts. 

ALM1 and ALM2

: show alarm status. 

 

 

INDEX

 

key

  -  This  key  is  used  to  access  the  programming 

menu and prompts. 

 

BACK

 

key

  -  This  key  is  used  to  go  back  to  the  previously 

reached prompt in the menu cycle. 

 

UP  /  MAX 

key  and

 

 

DOWN  /  MIN 

-

 

Used  to  increase 

and decrease parameters values, these keys are also used 
to display maximum and minimum values stored in memory. 

         

Special  FUNCTION  key 

-  This  special  function  key  is  used   

for pre-programmed functions as explained in the SPECIAL 
FUNCTION KEY section of this manual. 

2.

 

SPECIFICATIONS 

 

Power: 100 to 240 Vac/dc ±10 %; 50/60 Hz  

 

Max. Consumption: 10 VA 

 

Internal  resolution:  19500  levels,  display:  12000  levels  (-1999  a 
9999) 

 

Input sample rate: 5 per second 

 

Accuracy: Thermocouples J, K, T and N: 0.25 % of span 

±

1 ºC. 

 

 

Thermocouple E, R, S and B: 0.25 % of span 

±

3 ºC. 

 

 

Pt100: 0.2 % of span 

 

 

Current or linear voltage: 0.2% of the maximum range 

 

Minimum heating time: 15 minutes

 

 

Input impedance:  0-50 mV, Pt100 and thermocouples: >10 M

Ω 

                            0-5 V: >1 M

Ω 

 

0-20 mA, 4-20 mA: 22 

Ω 

 

Pt100 measurement: 3 wire circuit. Current 0.170 mA.                
PV Resolution of retransmission: 1500 levels, 550 

Ω 

max. 

 

Relays: SPST-NA - 3A / 250 Vac 

 

Digital Input: Dry contact or NPN open collector 

 

Auxiliary Voltage Source:  24 Vdc  (±10 %) / 25 mA máx. 

 

Operating temperature: 0 to 55 °C, Maximum RH: 80 % up to 30 ºC. 
For temperatures above 30 ºC, decrease 3 % per ºC. 

 

Approximate weight: 1 kg 

 

Dimensions: 310 x 110 x 37 mm (C x A x P) 

 

Protection: IP30 (when installed properly) 

3.

 

PROCESS VARIABLE INPUT - PV 

The Process Variable input type should be keyboard programmed by 
the user according to the codes shown on 

Table 1

 (refer to INPUT 

TYPE parameter "

in.typ

in.typ

in.typ

in.typ

"). 

TIPO 

CODE 

CARACTERÍSTICAS 

Tc j

Tc j

Tc j

Tc j

 

Range: -50 to 760 °C (-58 to 1400 °F) 

Tc h

Tc h

Tc h

Tc h

 

Range: -90 to 1370 °C (-130 to 2498 °F) 

Tc t

Tc t

Tc t

Tc t

 

Range: -100 to 400 °C (-148 to 752 °F) 

Tc e

Tc e

Tc e

Tc e

 

Range: -35 to 720 °C (-31 to 1328 °F) 

Tc n

Tc n

Tc n

Tc n

 

Range: -90 to 1300 °C (-130 to 2372 °F) 

Tc r

Tc r

Tc r

Tc r

 

Range: 0 to 1760 °C (-32 to 3200 °F) 

Tc s

Tc s

Tc s

Tc s

 

Range: 0 to 1760 °C (-32 to 3200 °F) 

Tc b

Tc b

Tc b

Tc b

 

Range: 150 to 1820 °C (302 to 3308 °F) 

Pt100 

pt100

pt100

pt100

pt100

 

Range: -199.9 to 530.0 °C (-327.8 to 986.0 °F) 

Pt100 

pt100

pt100

pt100

pt100

 

Range: -200 to 530 °C (-328 to 986 °F) 

4-20 mA 

Lin j

Lin j

Lin j

Lin j

 

Linearizes J. Adjustable range: -110 to 760 °C 

4-20 mA 

Lin h

Lin h

Lin h

Lin h

 

Linearizes K. Adjustable range.: -150 to 1370 °C 

4-20 mA 

Lin t

Lin t

Lin t

Lin t

 

Linearizes T. Adjustable range.: -160 to 400 °C 

4-20 mA 

Lin e

Lin e

Lin e

Lin e

 

Linearizes E. Adjustable range.: -90 to 720 °C 

4-20 mA 

Lin n

Lin n

Lin n

Lin n

 

Linearizes N. Adjustable range -150 to 1300 °C 

4-20 mA 

Lin r

Lin r

Lin r

Lin r

 

Linearizes R. Adjustable range 0 to 1760 °C 

4-20 mA 

Lin s

Lin s

Lin s

Lin s

 

Linearizes S. Adjustable range.: 0 to 1760 °C 

4-20 mA 

Lin b

Lin b

Lin b

Lin b

 

Linearizes B. Adjustable range.: 100 to 1820 °C 

4-20 mA 

linpt

linpt

linpt

linpt

 

Linearizes Pt100. Adj. range.:-200.0 to 530.0 °C 

4-20 mA 

linpt

linpt

linpt

linpt

 

Linearizes Pt100. Adj. range.: -200 to 530 °C 

0 -50 mV 

0

0

0

0

 - 

50

50

50

50

 

Linear. Adjustable range.: -1999 to 9999 

4-20 mA 

4

4

4

4

 - 

20

20

20

20

 

Linear. Adjustable range.: -1999 to 9999 

0 a 5 V 

0

0

0

0

 - 

5

5

5

5

 

Linear. Adjustable range.: -1999 to 9999 

0 a 50 mV 

c.0

c.0

c.0

c.0

 - 

50

50

50

50

 

User defined linearization 

4-20 mA 

c.4

c.4

c.4

c.4

 - 

20

20

20

20

 

User defined linearization 

0 a 5 V 

c.0

c.0

c.0

c.0

 - 

5

5

5

5

 

User defined linearization 

Table 1

 - Input type codes 

All input types are  factory calibrated and no additional calibration is 
required. Thermocouples are calibrated to NBS standards. RTD’s are 
calibrated to DIN 43760 (

α

=0.00385). 

Отзывы: