Novus myPCLab Скачать руководство пользователя страница 1

NOVUS AUTOMATION 

1/9

 

 

 

my

PCLab

 

INSTRUCTION MANUAL – V1.1x B

 

 

INTRODUCTION 

my

PCLab

 is a very compact Data Acquisition tool that connects to a PC via a USB port and monitors two universal input 

analog variables along with one digital input. From hobbyists to scientists, from simple technical tasks to complex 

engineering activities, 

my

PCLab

 can be an invaluable tool for on-line monitoring and data logging in school, laboratory 

research, machine data recording and industrial understanding. 
It comes with intuitive and easy-to-use Windows software which plots and records data, shows gauges, bargraphs and 

digital readouts. The USB port is accessed as a virtual serial port, which makes 

my

PCLab

  compatible with SCADA 

software with Modbus RTU driver or with any program with ASCII serial communication.  
Multiple units of 

my

PCLab

  can be connected to the same computer, easily expanding the number of inputs. The 

my

PCLab

 software can simultaneously communicate with multiple modules. 

This manual describes software installation and connection of input signals to a 

my

PCLab

 module. Instructions on using 

the software are available on its help system. 

 

Not compatible with Windows® 10. 

 

 

READ THIS RECOMMENDATION TO AVOID DAMAGE TO YOUR COMPUTER.

 

my

PCLab

 inputs are not electrically isolated from the USB port. Before connecting signals from sensors or 

transducers, make sure that they are not in contact with any source of electrical power (wires or conductive 

surfaces which may get energized). Input channels are not isolated from each other. 

SPECIFICATIONS 

Analog Input Signals: 

Configurable for channels 1 and 2. The input signals and measuring ranges are listed in the 

following table. 

 

Thermocouples

:  J, K, T, E, N, R, S and B types. 

Input Impedance >> 1 MΩ

 

 

Pt100

Three wires connection, 625 

µ

A bias 

current, α = 0.00385.

 

 

Linear Signals

0 to 50 mVdc: Input Impedance >> 1 MΩ

 

0 to 10 Vdc: Input Impedance = 1 MΩ. Available only in channel 1.

 

4 to 20 mAdc: Input Impedance: 22 Ω (+ 2,0 Vdc)

 

Input Type 

Maximum Range 

J

 Thermocouple 

-

130,0 to 940,0 °C (

-

202,0 to 1724,0 ºF)

 

K

 Thermocouple 

-

200,0 to 1370,0 °C (

-

328,0 to 2498,0 ºF)

 

T

 Thermocouple 

-

200,0 to 400,0 °C (

-

328,0 to 752,0 ºF)

 

E

 Thermocouple 

-

100,0 to 720,0 °C (

-

148,0 to 1328,0 ºF)

 

N

 Thermocouple 

-

200,0 to 1300,0 °C (

-

328,0 to 2372,0 ºF)

 

R

 Thermocouple 

0,0 to 1760,0 °C (

-

32,0 to 3200,0 ºF)

 

S

 Thermocouple 

0,0 to 1760,0 °C (

-

32,0 to 3200,0 ºF)

 

B

 Thermocouple 

500,0 to 1800,0 °C (932,0 to 3272,0 ºF)

 

Pt100

 RTD 

-

200,0 to 650,0 °C (

-

328,0 to 1202,0 ºF)

 

0 to 50 mVdc

 

Adjustable from -

32767 to +32767

 

0 to 10 Vdc (Channel 1)

  Adjustable from -

32767 to +32767

 

4 to 20 mAdc

 

Adjustable from -

32767 to +32767

 

myPCLab

 module sensors and signals 

Содержание myPCLab

Страница 1: ...ON TO AVOID DAMAGE TO YOUR COMPUTER myPCLab inputs are not electrically isolated from the USB port Before connecting signals from sensors or transducers make sure that they are not in contact with any...

Страница 2: ...ncy 500 Hz square wave no debounce Maximum input frequency 500 Hz square wave no debounce Accuracy 0 5 Ambient Temperature Sensor Internal thermistor Total Accuracy Thermocouples R S and B 0 25 of the...

Страница 3: ...ement The 3 wires must have the same length and gauge To connect a Pt100 with 2 wires connect terminals 7 and 8 channel 1 or 3 and 4 channel 2 THERMOCOUPLE WIRING Connections of channel 1 are on termi...

Страница 4: ...hannel 1 terminals 5 and 6 Observe indicated polarity DRY CONTACT DIGITAL INPUT WIRING Digital signals are connected to channel 3 terminals 1 and 2 The contact connected to digital input must not have...

Страница 5: ...select option Include this location in the search and type the path for the required files 6 If a warning message regarding Windows XP compatibility appears select Continue Anyway 7 The myPCLab driver...

Страница 6: ...tem SERIAL PORT COM PORT ASSIGNMENT A few seconds after connection of a myPCLab Windows operating system assigns a COM port number for communication The assigned COM port number will not change in fut...

Страница 7: ...myPCLab NOVUS AUTOMATION 7 9 WARRANTY Warranty conditions are available on our web site www novusautomation com warranty...

Страница 8: ...s of the Modbus master set the COM port number assigned to the device The USB port ignores all other serial communication parameters Communication Port Select the COM port number assigned to the myPCL...

Страница 9: ...ke Matlab Simulink HPVee Testpoint can also be configured to receive and parse measured data When operating in the auto send mode a myPCLab don t expect to receive any information from the USB port It...

Отзывы: