Coating Thickness Gauge NOVOTEST TP-2020 

Page 28 

3.3.3 Warranty for repaired or replaced parts 

All branded parts of NOVOTEST installed during the warranty repair apply to the NOVOTEST 

warranty (up to the end of the warranty period). 

The spare parts replaced during the warranty service, shall not be returned to the device owner. 

 

3.3.4 Wearing parts 

The parts wearing during the device operation are divided into two main categories. The first part 

includes the parts that need to be replaced or adjusted with the frequency stipulated by the maintenance 
schedule of the device, and the second part includes the wearing parts, which frequency of replacement 
or adjustment depends on the conditions of the product operation. 

 

3.3.4.1 The parts replaced during the maintenance 

The parts listed above have a limited service life and need replacement or adjustment with the 

frequency stipulated by the maintenance schedule of the device. For these parts, the basic warranty 
applies before the first replacement or adjustment. The warranty period for each part shall not exceed 
the limitations (by the time of operation of the device or working hours), specified in the conditions of 
the basic warranty. 

 

built-in batteries; 

 

gaskets if they are removed due to adjustment; 

 

oil and working fluids. 
 

3.3.4.2 Wearing parts 

The parts listed below have limited service life or need to be replaced (adjusted) due to the damage. 

However, these parts are subject to the basic warranty of NOVOTEST for 12 months: 

 

probes and their components; 

 

connecting cables; 

 

parts and mechanisms exposed to mechanical impact during operation. 
 

Note: The parts wearing due to friction (such as movable parts of measuring probes, ultrasonic 

piezoelectric probes, support arm etc.) are not covered by the basic NOVOTEST warranty if these parts 
are damaged due to wear and tear during the device operation. However, if in the warranty period these 
parts fail due to defect of material or workmanship, they shall be repaired or replaced under the basic 
warranty. 

 

3.3.5 Owner obligations 

The «Operating manual» and «Datasheet» contains the information about right operation and 

maintenance of your device. 

Proper operation and maintenance of the device will help avoid costly repairs caused by incorrect 

operation, negligence or improper maintenance. Besides, following our recommendations will extend 
the service life of the device. Therefore, the device owner should: 

 

If any defect or fault is found, submit the device to NOVOTEST or the authorized dealer of 
NOVOTEST for a warranty repair as soon as possible. This can minimize the repair required 
for the device. 

 

Perform maintenance of your device in line  with the recommendations of the operating 
manual and passport. 
 

Note: Failure to perform the timely maintenance of the device in accordance with the prescribed 

schedule will void your rights to the warranty repair or replacement of defective parts. 

 

 

Use only branded spare parts and couplants of NOVOTEST (with appropriate labels). 

Содержание TP-2020

Страница 1: ...Coating Thickness Gauge NOVOTEST TP 2020 Operating Manual 2021...

Страница 2: ...llation 11 2 2 3 Probe connection 11 2 3 Intended use 12 2 3 1 Turning on 12 2 3 2 Working in MEASUREMENT mode 13 2 3 3 Zeroing of the probe 14 2 3 4 Working in CALIBRATION mode 15 2 3 5 Working in AR...

Страница 3: ...27 3 3 Warranty 27 3 3 1 Basic warranty 27 3 3 2 Extended warranty 27 3 3 3 Warranty for repaired or replaced parts 28 3 3 4 Wearing parts 28 3 3 5 Owner obligations 28 3 3 6 Warranty restrictions 29...

Страница 4: ...ruction and actions as well as information necessary for the correct use of the product Before use study this document as the device is to be used by those familiar with the principles of operation an...

Страница 5: ...1 2 V Amperage max mA 100 Time of continuous operation min h 20 Weight of the electronic unit and battery max g 250 Weight of the probe max g 150 Operating temperature C 20 40 Air humidity max 98 at...

Страница 6: ...is indicated in the passport of the device 1 4 Application of probes Fig 1 1 show the probes of different types F 0 3 F 0 5 F 2 F 5 NF 2 M 12 M 30 M 60 DSH ST STMD Figure 1 1 Probes F probe The probe...

Страница 7: ...oatings M30 0 30000 m 0 03h 0 02 mm Testing of mastic coatings M60 0 60000 m 0 03h 0 03 mm Testing of mastic coatings NF 2 0 2000 m 0 03h 0 002 mm Testing of anodic oxide films and paint coatings ST 4...

Страница 8: ...he keyboard buttons and their functions turning on and off left functional button right functional button navigation up in the device menu selection of the measuring unit navigation down in the device...

Страница 9: ...sessed by checking the modes of its operation and checking the possibility of measuring the thickness by the thickness blocks reference blocks The discrepancy between the readings of the device should...

Страница 10: ...ure that there is no mechanical damage to the processing unit 4 probe 10 connector 7 and connecting cable 9 2 2 2 Battery installation Place a battery into the battery compartment 5 after pushing and...

Страница 11: ...rasp its housing in a corrugated area do not pull the cable Figure 2 3 Manipulating connectors 2 3 Intended use 2 3 1 Turning on Turn the device on by pressing on the control panel until a short term...

Страница 12: ...ic display The measured data can be displayed in several modes see c 1 7 button is used to switch between the modes and when the button pressed the menu of displaying modes will appear on the screen N...

Страница 13: ...ed part 2 Then set the probe on the prepared sample or object without coating upright and push it down fig 2 11 without wiggling Figure 2 11 Setting of the probe on the uncoated object Warning Do not...

Страница 14: ...l corresponds to the base material of calibration Ferromagnetic base Non ferromagnetic base Base 1 Base 2 for a specific material of coating Dielectric coating Coating 1 Coating 2 Coating 3 Coating 4...

Страница 15: ...of the following parameters fig 2 17 LANGUAGE selection of the language of the device menu English Russia and others are available BRIGHTNESS changing of the display brightness from 0 to 100 discrete...

Страница 16: ...ttings of the probe This is needed to resume proper calibration after incorrect settings 2 3 7 2 Downloading of calibration backups The saved calibrations can be downloaded from the probe memory This...

Страница 17: ...e firmware version 2 3 9 Measurements 1 Connect the probe and turn the device on by pressing 2 Zero the probe see c 2 3 3 3 Set the probe on the test object or coated part upright and press it to down...

Страница 18: ...pressing 5 Check the accuracy of zero setting and make sure that the readings of the device do not exceed 2 m 6 Measure the test object If the coating thickness is identical to the coating thickness o...

Страница 19: ...nnect the DSH probe to the device 2 2 3 2 Turn the device on 2 3 1 3 Set the base material in the device settings Non ferromagnetic base and set the coating material to Dielectric coating 4 Set zero o...

Страница 20: ...old 2 4 Connection of the device to PC 2 4 1 Software installation Connecting the device to a PC user can transfer the information stored on the memory card to a PC To connect the device to a PC 1 Cop...

Страница 21: ...play 2 4 2 Working with AWP TP1M software At the first start of the program the window will appear where the archive location should be chosen for saving of the measurement information fig 2 32 and th...

Страница 22: ...and Russian websites or planet international website in English and the website will be opened in the browser by default 2 4 3 Data transfer to PC To drop the data saved in the device memory connect t...

Страница 23: ...rements to a PC 2 4 4 Data processing on PC In OPERATION WITH ARCHIVE section user can view print copy move and delete the data from archive fig 2 35 Each record is saved with a full information about...

Страница 24: ...DIAGRAM HISTOGRAM and measurement results Maximum Minimum Deviation Average Standard deviation Mean square deviation Variation coefficient The homogeneity of the series Number of measurements This inf...

Страница 25: ...he preview window of the testing protocol In the Screen copies section user can save the display images on the device in real time and the device should be connected to a PC To save the measurement pr...

Страница 26: ...The following warranty information is valid for all NOVOTEST products The manufacturer guarantees the conformity of the device to the requirements of the technical conditions under the user s complian...

Страница 27: ...e replaced adjusted due to the damage However these parts are subject to the basic warranty of NOVOTEST for 12 months probes and their components connecting cables parts and mechanisms exposed to mech...

Страница 28: ...turer Use of batteries or other components of poor quality Power line surge Failure a timely repair of damage found during scheduled maintenance Factors outside the scope of control of NOVOTEST for ex...

Страница 29: ...warranty repair of the device So always make sure that the authorized service center of NOVOTEST puts a stamp in the right place under the record about the performed procedure Table 3 1 The maintenanc...

Страница 30: ...place of storage should be free from vapors of aggressive media acids alkali and direct sunlight The device shall not be exposed to rapid shocks falls or strong vibrations The devices shall be placed...

Страница 31: ...______________________ __________________________________________________________________________________ __________________________________________________________________________________ ___________...

Отзывы: