ACO203XL
16
EN
Inserting the battery (Fig. 3)
Slide the battery into the device as illustrated until it clicks into place.
Pos: 41 /RVT/Kurzbeschr eibung/Akku allgemei n/Akku Z ustandsanzeig e/AC O/ECO202, AC O202XL, AC O/ECO203 @ 0\mod_1382445046754_18.docx @ 1446 @ @ 1
Battery charge indicator (Fig. 2)
The battery charge is displayed when button (B) is pressed. The number of LEDs lit up denotes the
battery charge. One flashing LED indicates a maximum power reserve of 10%. The battery must be
charged soon.
If the battery is inserted in the press device while the battery charge is being checked, the last
pressing operation must have been completed at least 1 minute prior to this. Otherwise the display will
be inaccurate.
Pos: 42 /RVT/Kurzbeschr eibung/Ger ät + Akku/Info welcher Akku/18V: ACO/EC O202, ACO202XL, AC O/ECO203 @ 1\mod_1435131784732_18.docx @ 12829 @ 2 @ 1
7.7 ACO203XL and battery
Information!
The ACO203XL press device must only be operated with 18 V lithium-ion
rechargeable batteries. The 18 V battery must only be used in the appropriate
press devices.
Pos: 43 /RVT/Kurzbeschr eibung/Ger ät + Akku/längere Nichtbenutzung/AC O102, AC O152, ACO/EC O202, ACO202XL, AXI/AAP102 @ 0\mod_1382607497309_18.docx @ 1524 @ @ 1
Feature of the press device after extended periods out of use or when changing the battery:
If the press device is out of use for approx. 30 minutes or the battery is reinserted, it switches off. No
LED is lit up any longer. Press the start button (1) briefly to start the press device.
Pos: 44 /RVT/Kurzbeschr eibung/Ger ät + Akku/entl adener Akku/ACO102, AC O152, ACO/EC O202, ACO202XL, ACO401, AC O/ECO203 @ 0\mod_1382607696426_18.docx @ 1532 @ @ 1
Feature of the press device when the battery is empty:
When a pressing operation begins, a check is made to determine whether the battery charge is
sufficient to complete the pressing operation. If this is not the case the device does not start. The
green LED (2) flashes.
If the green LED (2) flashes following a pressing operation, the pressing operation was carried out
correctly. The battery must be recharged prior to the next pressing operation.
Pos: 46 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/1c - Quetschg efahr Fi nger AC O202XL @ 1\mod_1428473874657_18.docx @ 10847 @ 12 @ 1
8 Commissioning and operation
8.1 Preparing the ACO203XL
CAUTION!
Fingers risk being crushed if the device is operated without a press
jaw/adaptor jaw (Fig. 4)
If no press jaw/adaptor jaw is fitted, fingers could be placed in the at-risk zone. Fingers
could be crushed when the device is started.
Therefore:
– Do not operate the device without the press jaws.
– Keep your fingers away from the at-risk zone.
CAUTION!
Fingers risk being crushed if the device is operated with the finger guard
incorrectly adjusted (Fig. 8)
If the finger guard has not been slid forwards when shorter press jaws are fitted, fingers
could be placed in the at-risk zone. Fingers could be crushed when the device is
started.
Therefore:
– Do not operate the device without having slid the finger guard forwards if shorter
press jaws have been inserted (Fig. 9).
– Keep your fingers away from the at-risk zone.
Pos: 47 /RVT/Inbetri ebnahme und Betrieb/Ger ät vorberei ten/2 - Ger äteschaden d. Hal tebolzen ACO102, AC O152, ACO202XL, ECO301, AF P/EFP202 @ 0\mod_1382615981245_18.docx @ 1553 @ @ 1