USI status messages
These status messages are triggered by the signal interface. They provide information on whether cer-
tain signals are present.
Fig. 56: Example of a USI status message.
Status message
Cause
USI pause
Signal
usi.pause
is active
USI feed
Signal
usi.feed
is active
Table 19: These USI status messages may occur.
USI status messages are only shown in the “Ready” display.
USI status messages may occur at the same time as USI status messages (see above). If this hap-
pens, warnings are displayed with priority.
Error messages
Background color = red
Error messages
must be acknowledged by the operator as the triggering event or fault endangers nor-
mal operation. A checkmark symbol can be seen in the bottom right corner of the message window
above key 4. The message appears in the display until the fault has been rectified and acknowledged
with key 4.
Blocking error messages
are messages that occur as a result of serious errors. There is no checkmark
symbol in the message window, i.e. the message cannot simply be acknowledged by pressing a key.
The error state can only be terminated by a "warm start" (press keys 1+2+3) or by switching off the
printer.
General software errors
Errors in the firmware can never be completely ruled out. Such errors are described in the error direc-
tory as "General software errors". They can only be corrected by the manufacturer.
► Switch the printer off and, after 30 seconds, on again. If the fault repeatedly occurs, please contact
our technical service.
Easy Plug errors
Errors in the Easy Plug code can be detected much easier with the following setting:
Printer Language
>
EasyPlug Setting
>
EasyPlug errors
= “Strict handling”
The Easy Plug command, which caused the error, is displayed after approx. 2 seconds in the lower
display line. The displayed text is up to 30 characters long and is scrolled automatically.
If a single character caused the error, this character is marked with “>> <<” in the display text, to facili-
tate the detection.