Service manual
XLP 504 / XLP 506
05/2018 | 09
138
The value set here remains when the factory settings are carried out.
Realtime Clock
Setting the realtime clock (date and time). Those data can be processes using the Easy Plug #YC,
#YS or #DM commands.
Head-sensor dist
(Distance between printline and label sensor)
Parameter appears only in service mode.
Special function for setting non-standard punch sensors. Such sensors can be applied in special
application devices ("Nistan").
The value x is the distance between thermal edge and punch sensor in millimeters.
0 = disabled (the regular punch sensor is used)
A „non standard sensor“ must be installed and connected instead of the regular punch sensor.
Free store size
By setting this parameter, a part of the memory is reserved, which the printer firmware can use if
necessary (dynamic memory allocation). If this memory area is dimensioned too small, the printer
firmware can not work and the error message „8856 Free store size“ shows up.
The more memory is allocated using this parameter, the less memory is available for print jobs.
A good advice is to increase the set value step by step, starting with the minimum of 4 MB, until
the status message 8856 ("Free store size", what means the memory area is low) does no longer
appear during data conversion.
Overview of the set memory areas: see parameter
Ram disk size
A part of the printer memory can be identified as a RAM disk. The RAM disk can be used in the
same way as the Compact Flash Card, e.g. for storage of logos or fonts.
With the parameter Ram disk size, the customer can set the size of the RAM disk to his needs. Be
aware, that RAM disk memory is not available for print picture buildup. Use of much RAM disk me-
mory reduces the picture buildup rate of the printer.
Switching the printer off extinguishes the memory content! Fonts, logos etc., which were loaded
on the RAM disk, must be loaded again after switching the printer off.
Settings
Default setting
Step width
Easy Plug
dd.mm.yyyy hh:mm
--
--
--
Setting range
Default setting
Step width
Easy Plug
[0..400] mm
0 mm
1 mm
#PC2016
Setting range
Default setting
Step width
Easy Plug
[4096...MAX
a
] KByte
a) Maximum size, depends on the memory equipment and usage of the printer
4096 KByte
256 KByte
#PC2048
Setting range
Default setting
Step width
Easy Plug
[128...MAX
a
] KBytes
a) Maximum size, depends on the memory equipment and usage of the printer
512 KBytes
128 KBytes
#PC2046
Содержание XLP 504
Страница 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Страница 2: ......
Страница 218: ...Service manual XLP 504 XLP 506 05 2018 04 218 Malfunctions System Memory Font downl area System Memory Free store size ...
Страница 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Страница 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...