Service manual
XLP 504 / XLP 506
05/2018 | 09
132
• If a further start signal arrives, before the current label is completely printed.
•
Only with I/O board
: If a reprint is requested, before the first label after powering on is printed.
• If a start signal arrives and no printjob is loaded.
If a product start error occurs, the machine stops and displays the appropriate status message.
If an I/O board or an USI is installed, the following output signals are activated (set low):
– ERROR\
– MACHINE STATUS\
•
On
: Start errors are worked up (the printer stops!)
•
Off
: Start errors are being ignored
Product length
Function for operation with product sensor.
If this function is activated, the printer ignores all start signals until the product has passed the dis-
pensing edge
Current mode
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ or „Intern. rewinder“
The setting of this parameter influences the impact of the paramters Min rew. current and Max rew.
current
•
Table values
: Display of the automatically calculated motor current chart PWM values (in %).
On the base of this setting, the printer calculates the motor current values for
Min rew. current
and
Max rew. current
out of print speed and material width. The calculated values appear as default
100%
•
Absolute values
: With this setting, the printer doesn´t calculate and doesn´t adapt to material
width and print speed. The set values for
Min rew. current
and
Max rew. current
are given to the out-
put stage without a modification. The valueas appear as absolute values.
The setting „Absolute values“ should only be used by especially trained personal!
Min rew. current
(Minimum rewinder current)
Only visible in service mode
Only if
Options > Selection > Periph. device
= „Dispenser“ or „Intern. rewinder“
Setting range
Default setting
Step width
Easy Plug
[0.0…1999.9] mm
0.0 mm
0.1 mm
#PC6017
Settings
Default setting
Step width
Easy Plug
Table values, Absolute values
Table values
--
#PC2501
Setting range
Default setting
Step width
Easy Plug
[50...200]%
110%
1%
#PC2504
a
a) If Options > Dispenser > Current mode = „Table values“
[0...750]
110
1
#PC2502
b
b) If Options > Dispenser > Current mode = „Absolute values“
Содержание XLP 504
Страница 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Страница 2: ......
Страница 218: ...Service manual XLP 504 XLP 506 05 2018 04 218 Malfunctions System Memory Font downl area System Memory Free store size ...
Страница 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Страница 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...