Service manual
XLP 504 / XLP 506
05/2018 | 09
131
There are two ways of setting back the counter:
• Set the parameter
Display mode
(see above) to "Job rest quant." , then back to "Dispense coun-
ter" and confirm by pressing the o. k. key.
• Reduce the displayed number.
Application mode
Only if
Options > Selection > Periph. device
= „Dispenser“.
•
Safe mode
: A start signal is required to draw the next label back under the print head. This set-
ting bears advantages for label material with a strong adhesive, which would not stay attached
to the applicator when the backing paper is fed backwards.
•
Immediate mode
: After the just printed label has reached the dispense position, the following
label is drawn back under the print head. The dispensed label stays attached to the applicator.
Preconditions:
• With foot switch:
Options > Start print mode
= „Pulse rising“ or „Pulse falling“
• With I/O board
: Options > I/O Board > Start print mode
= „Pulse rising“ or „Pulse falling“
Start source
Only if
Options > Selection > Periph. device
= „Dispenser“.
Choose a signal source for the start signal:
•
Foot switch
: Optional foot switch is used to generate the start signal.
•
Light barrier
: Photoelectric switch at the dispensing edge which detects the taking off of the dis-
pensed label.
The setting "Light barrier" is unsuitable for product sensors! Product sensors must be
connected to the I/O board!
Start offset
Function for operation with product sensor.
Use this parameter to set the distance between product sensor (light barrier) and dispensing edge.
The recommended delay time is calculated of the "Start delay" distance and the conveyor speed (=
print speed in cases of direct application).
Start error stop
Function for operation with product sensor.
Determines the reaction of the machine on a product start error. A product start error occurs in the
following cases:
Settings
Default setting
Step width
Easy Plug
Safe mode, Immediate mode
Immediate mode
--
#PC2035
Settings
Default setting
Step width
Easy Plug
Foot switch, Light barrier
Light barrier
--
#PC2039
Setting range
Default setting
Step width
Easy Plug
[15.0...2999.9] mm
15.0 mm
0.1 mm
#PC6004
Settings
Default setting
Step width
Easy Plug
On, Off
On
--
#PC3009
Содержание XLP 504
Страница 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Страница 2: ......
Страница 218: ...Service manual XLP 504 XLP 506 05 2018 04 218 Malfunctions System Memory Font downl area System Memory Free store size ...
Страница 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Страница 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...