Installation and Maintenance Instructions for 

Cabin Units Type RS35X-CX0-E for CCS MicroVent System 

1.

 

Application

 

2.

 

Handling

 

2.1

 

Marking

 

2.2

 

Weight

 

2.3

 

Transport

 

3.

 

Storage

 

4.

 

Installation

 

5.

 

Duct connections

 

6.

 

Electric connection

 

7.

 

Wiring diagram

 

8.

 

Thermostat

 

9.

 

Regulation

 

10.

 

Parts included

 

11.

 

Maintenance

 

 

1.  Application 

Cabin units from Novenco are used 

for heating, distribution and 

discharge of air from high-pressure 

air handling units to rooms and 

cabins on ships, oil platforms etc.   

2.  Handling 

2.1  Marking 

All cabin units are marked with 

standard plates (figure 1). The plates 

provide the name and address of 

Novenco as well as the product  type 

and serial number, e.g. RS35X.  The 

serial number is unique for each unit.   

In addition, the maximum power 

consumption is also written on the 

plates.  The control boxes (CCU) are 

also marked with plates showing type, 

ID and serial number.   

 

Figure 1 

2.2  Weight   

On request from the customer 

Novenco can add the weights of the 

cabin units to the marking of the 

units.   

Type 

Weight [kg] 

Dim. (HxWxL) [mm] 

RS 35X 

16.5 

600x450x175 

Diffuser 

1.5 

425x425x90 

Total 

18.0 

—— 

Table 1 

2.3  Transport   

Cabin units from Novenco are packed 

and delivered on pallets to allow 

fork-lift transport.   

3.  Storage 

The cabin units must be stored in a 

dry place and at temperatures not 

exceeding 45

o

C.  Furthermore, it is 

recommended to avoid long time 

storage of the units in humid air 

conditions (60% RH or more). This is 

because  of risk to the internal 

electrical components, which are 

unprotected against rust.   

4.  Installation 

The cabin units are available for 

ceiling suspension (figure 2). Units are 

delivered with four suspension 

brackets (A) incl. supply parts (B) for 

fastening to the ceiling  and sides of 

the units.   

 

It is important that the cabin units are 

fastened to prevent sound nuisances, 

caused by vibration.   

5.  Duct connections 

The cabin units are designed for 

connection to large duct systems on 

e.g. ships. Connect the cabin units to 

the systems using insulated flexible 

hoses and clamping rings.   

It is important that the flexible hose is 

straightened out and that the length 

does not exceed 300 mm (figure 3).   

 

Figure 3 

6.  Electric connection 

Power to the unit is supplied by 

connecting 230V  power cables to the 

terminals L, N and PE as shown in the 

wiring diagram.  Refer also to the 

electric diagram placed on the inside 

of the lid of the terminal boxes.   

Cables must be fastened by cable 

glands before feeding the Cabin units. 

For room thermostat, its cable must be 

tied up and fixed. Refer to the wiring 

diagrams for correct  connection of 

cables.   

The required output from the heating 

elements is selected on the three 

toggle switch (400, 800 and 1200 W) in 

the outflow connection of the cabin 

units.   

7.  Wiring diagram 

See figure 4 on page 3.   

8.  Thermostat 

The cabin units are equipped with 

both the temperature sensors and the 

mechanical thermostats 

for 

overheating protection.  The sensor 

has  a  programmed  reset function 

while the mechanical thermostat has a 

manual reset function.   

The sensor will switch off the heating 

and alarm will on, when the 

temperature  within the cabin unit 

exceeds 70 

o

C, and back on when the 

heating elements have cooled 

sufficiently off.   

 

Figure 5 

If the  sensor  fails, the mechanical 

thermostat will switch off the heating, 

when the temperature exceeds 110 

o

C. 

To re-activate the heating elements, 

switch off the current to the cabin unit 

in the fuse box. Remove  the bottom 

part of  the diffuser by gently pulling 

in the corners of the part. The manual 

thermostat can then be accessed and 

the small pin on the thermostat 

Figure 2 

MU 14633 1212 