Operation
Chapter 3
ProPak6 Installation and Operation User Manual Rev 4
53
Figure 20: Steadyline UAL- Warning Limit Example
Figure 21: Steadyline UAL - Out of Bounds Example
A
Position type is OPERATIONAL.
Higher accuracy corrections are lost. The receiver changes to a lower accuracy solution.
Steadyline operates in Maintain mode while the solution accuracy remains within the Operational
limit.
B
The solution accuracy exceeds the operational limit. The position type changes to WARNING.
The Steadyline mode changes from Maintain to Transition.
C
The solution accuracy moves back within the operational limit. The position type changes to
OPERATIONAL.
The Steadyline mode remains in Transition mode.
D
The solution offset is removed.
The Steadyline mode changes from Transition to Maintain.
Operational
Limit
Warning
Limit
Operational
Limit
Warning
Limit
A
B
C
D
A
The position type is OPERATIONAL.
Higher accuracy corrections are lost. The receiver changes to a lower accuracy solution.
Steadyline operates in Maintain mode while solution accuracy remains within the Operational limit.
B
The solution accuracy exceeds the operational limit. The position type changes to WARNING.
The Steadyline mode changes from Maintain to Transition.
C
The solution accuracy exceeds the warning limit. The position type changes to OUT_OF_BOUNDS.
Steadyline is disabled.
Operational
Limit
Warning
Limit
Operational
Limit
Warning
Limit
A
B
C