APPENDIX C LN-200 IMU in Universal Enclosure
Important!
Assemble in accordance with applicable industry standards. Ensure all ESD measures are
in place, in particular, use a ground strap before exposing or handling any electronic items, including the
IMU. Take care to prevent damaging or marring painted surfaces, O-rings, sealing surfaces, and the
IMU.
The following procedure provides the necessary information to install the LN-200 sensor into the Universal
Enclosure (NovAtel part number 01018590), both illustrated below. The steps required for this procedure are:
l
Disassemble the Universal Enclosure
l
Install the LN-200 Sensor Unit
l
Reassemble the Universal Enclosure
Figure 117: Required Parts
Use thread-locking fluid on all fasteners except for the cable harness connectors.
Torque values for all fasteners, including those for the cable harness screws, are as follows:
Size 6-32: 0.79-0.90 N-m (7.0-8.0 lb-in)
Size M4: 1.36-1.58 N-m (12.0-14.0 lb-in)
C.1 Disassemble the Universal Enclosure
Disassemble the Universal Enclosure as follows: