FlexPak6 Technical Specifications
Appendix F
OEM6 Family Installation and Operation User Manual Rev 12
192
Table 47: FlexPak6 I/O Port Pin-Out Descriptions
The FlexPak6 provides an output voltage on pin 4 of COM2 (POUT) that matches the voltage
used to power the FlexPak6.
The FlexPak6 can accept voltages up to 36 VDC, which is greater than the RS-232 specified
maximum 25 VDC. As a result, you can damage equipment that is connected to COM2 by
sending voltages higher than the RS-232 specification allows.
Pin
Signal Name
Input/Output
Signal Descriptions
1
Input/Output
2
Input/Output
3
CAN1+
Input/Output
4
No connect
5
GND
Digital ground
6
ETH_TD-
Input/Output
7
ETH_RD-
Input/Output
8
CAN1-
Input/Output
9
MODE
Input
When grounded (e.g., connected to pin 5), enables RS-422 mode
for COM2. RS-232 is the unconnected default
10
EVENT2
Input
Mark 2 input. This input has in internal pull-down and buffers the
input to the OEM628 card
11
EVENT1
Input
Mark 1 input. This input has in internal pull-down and buffers the
input to the OEM628 card
12
VARF
Output
Variable frequency out
13
ERROR
Output
Indicates a fatal error when high. The antenna port LED also turns
red during a fatal error
14
PV
Output
Valid position available. The antenna port LED also turns green for
a valid position
15
PPS
Output
Pulse per second