72
EuroPak-15a Receiver User Manual Rev 5
Chapter 6
Data Logs
6.3.1
AGCSTATS
Automatic Gain Control Status
This log provides status information for the automatic gain control mechanism and details of the parameters it
is currently using.
Log Type: Synch
Message ID: 630
Field
Field
Name
Data Description
Format
Binary
Bytes
Binary
Offset
1
header
This field contains the message header, in
ASCII
or
Binary
format.
See
.
H
0
2
# RF decks
Number of RF decks reported in this message.
Ulong
4
H
3
AGCword
AGC status word (see
Ulong
4
H+4
4
gain
AGC gain (0 to 99999)
Ulong
4
H+8
5
pulse width
VARF pulse width
Ulong
4
H+12
6
modulus
VARF modulus
Ulong
4
H+16
7
bin1
A/D bin 1 (decimal percentage)
Double
8
H+20
8
bin2
A/D bin 2 (decimal percentage)
Double
8
H+28
9
bin3
A/D bin 3 (decimal percentage)
Double
8
H+36
10
bin4
A/D bin 4 (decimal percentage)
Double
8
H+44
11
bin5
A/D bin 5 (decimal percentage)
Double
8
H+52
12
bin6
A/D bin 6 (decimal percentage)
Double
8
H+60
13
noise floor
Calculated noise floor
Double
8
H+68
14
Reserved
Double
8
H+76
15
Double
8
H+84
16...
Next RF deck, offset = H+ 4 + (#RF *88) Bytes
32-bit CRC (ASCII and Binary only)
Hex
4
H+ 4
(#RF*88)