NWB & NWB-HC IM28 OCT 2014
Page 21
Instruction Manual NWB & NWB-HC IM 28 OCT 2014
If you select the Dryer Status from the
Advanced Functions screen,
all of the dryer
parameters can be monitored
.
Reactivation inlet and outlet
temperature
Process inlet and outlet temperature
System dew point
Calculated desiccant wheel RPH
The graphics on this screen will change
appearance in accordance with the mode of
operation.
Intelligent Regen is an energy-saving feature
that is activated at the factory prior to
shipment. See below.
INTELLIGENT REGEN - NO ENTRY REQUIRED
Shipped Configured and Enabled
Intelligent Regen constantly monitors the regeneration inlet and outlet temperatures and controls
them to optimize the energy and dew point performance of the dryer. The control will lower (or raise)
the regeneration inlet temperature by 5 F. (2.4 C) each time the desiccant wheel rotates to ensure
that adequate, but not excess heat, is used to maintain the dryer dew point performance while
insuring that no excess heat is used and wasted. Once the dryer has optimized itself, changes
cease. The system insures the best dryer performance despite the materials processed, their
moisture level or any changes in dryer processing rate thereby saving energy and improving
performance.
11.2 Dryer Alarms (Level 3)
11.3 Dryer Status (Widely Used By processors)
Alarm settings are pre-set at NOVATEC
but Level 3 personnel can re-set them.