ELECTROMAGNETIC INTERFERENCE STANDARDS
PAGE
|
24
Remote Interlock
Indicator
Rear panel indicator
(Green/Red)
Illuminates green when
Remote Interlock
circuitry is closed.
Illuminates red when
interlock circuitry is
open.
No
No
Yes
Over Temperature
Protection
Circuit Element
Temperature shutdown
occurs if temperature
of the laser tube rises
above safe operating
limits
No
No
Yes
Temp Indicator
Rear panel indicator
(Green/Red).
Illuminates green when
laser temperature is
within operating limits,
changing to red when
thermal limits are
exceeded.
No
No
Yes
Warning Labels
Exterior
Labels attached to
various external
housing locations.
Warnings to personnel
of potential laser
hazards.
Yes
Yes
Yes
1
Not available 0n p100/150 OEM Lasers
When integrating NOVANTA® p100/150 OEM lasers, the Buyer and/or integrator of the end system is
responsible for meeting all applicable Standards to obtain the CE mark. To aid this compliance process,
NOVANTA testing program has demonstrated that p100/150 lasers comply with the relevant
requirements of 2014/30/EU, the Electromagnetic Compatibility Directive, as summarized in Table 2-2
below.
Table 2-2 European Union Directives
Applicable Standards/ Norms
2014/30/EU
Electromagnetic Compatibility Directive
2014/35/EU
Low Voltage Directive
2015/863/EU
RoHS Directive
EN 61010-1:2010
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1:
General Requirements
EN 61000-6-4
Radiated Emissions Group 1, Class A
EN 61000-6-4
Conducted Emissions Group 1, Class A
EN 61000-6-2
Electrostatic Discharge Immunity
EN 61000-6-2
RF Electromagnetic Field Immunity
EN 61000-6-2
Electrical Fast Transient/Burst Immunity
EN 61000-6-2
Conducted RF Disturbances Immunity
After a laser or laser processing system has met the requirements of all applicable EU Directives, the
product can bear the official compliance mark of the European Union as a Declaration of Conformity.
Содержание SYNRAD Pulstar p100
Страница 1: ...ENGINEERED BY SYNRAD p100 150 Lasers User Manual...
Страница 17: ...NOMENCLATURE CONTINUED PAGE 12 Nomenclature Continued Figure 1 2 Anatomy of a model number...
Страница 23: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 18 p100 label locations...
Страница 24: ...ADDITIONAL LASER SAFETY INFORMATION PAGE 19 p150 label locations...
Страница 30: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 25 Figure 2 1 p100 Declaration Document...
Страница 31: ...ELECTROMAGNETIC INTERFERENCE STANDARDS PAGE 26 Figure 2 2 p150 Declaration Document...
Страница 39: ...FOCUSING OPTICS PAGE 34 Table 3 1a Dew point temperatures in Fahrenheit Dew Point Table F...
Страница 46: ...OPERATION MODES PAGE 41 Figure 3 6 p150 pulse profile 37 5 duty cycle at 10 kHz...
Страница 49: ...USER I O CONNECTION SUMMARY PAGE 44 Figure 3 9 User I O connector pinouts...
Страница 68: ...REMOTE INTERLOCK FUNCTIONS PAGE 63 Figure 3 21 p100 150 outline mounting drawings pg 1 of 2...
Страница 70: ...REMOTE INTERLOCK FUNCTIONS PAGE 65 Figure 3 23 p100 150 packaging instructions...
Страница 71: ...REMOTE INTERLOCK FUNCTIONS PAGE 66 Figure 3 24 p150 outline and mounting...
Страница 78: ...OPERATIONAL FLOW CHART PAGE 73 Operational flow chart Figure 4 1 p100 150 operational flowchart...
Страница 79: ...STATUS LEDS PAGE 74 Status LEDs Table 4 2 p100 p150 Input output LED Status Signals...
Страница 88: ...This page is left blank intentionally...