INITIAL START-UP
PAGE
|
52
9
Lifting Handles – allow you to safely lift and move the laser. After laser installation, all three
handles can be removed if additional clearance is necessary.
10
GND (–) Terminal – M10 × 1.5 threaded stud provides connection point for negative (ground) side
of the 48 VDC power supply.
11
48V POWER Terminal Block – re48 VDC from the 48 VDC power supply. Fasten the
positive DC Power Cable using the supplied M10 × 1.5 bolt at the indicated connection point.
12
Ethernet Port – provides the connection point for a TCP/IP web-based interface between your
computer or network and the i401 laser.
Initial start-up
The Initial start-up section includes subsections:
•
With a UC-2000 Controller
•
Without a UC-2000 Controller
Danger: Serious Personal Injury
This Class 4 laser product emits invisible infrared laser radiation in the 10.6
μ
m CO2 wavelength
band. Since direct or diffuse laser radiation can inflict severe corneal injuries, always wear eye
protection when in the same area as an exposed laser beam. Do not allow the laser beam to
contact a person. This product emits an invisible laser beam that is capable of seriously burning
human tissue.
Al
b
f th b
’
th d l
b
bl
k hil t ti
Danger: Serious Personal Injury
Remote interlock faults are not latched on i401 OEM lasers. Clearing the fault condition re-enables
the RDY indicator and the laser will fire after the five-second delay provided the SHT indicator is lit
and a PWM Command signal is applied. Because exposure to 10.6
μ
m CO
2
laser radiation can inflict
severe corneal injuries and seriously burn human tissue, the OEM or System Integrator must ensure
that appropriate safeguards are in place to prevent unintended lasing.
Danger: Serious Personal Injury
The use of the Quick Start Plug bypasses the laser’s safety interlock function, potentially exposing
personnel in the area to invisible infrared laser radiation.
The Quick Start Plug is intended only for initial testing and troubleshooting by qualified personnel.
In normal operation, the laser’s Remote Interlock input should be connected to the machine’s
safety interlock circuitry.
Содержание i401
Страница 1: ...ENGINEERED BY SYNRAD i401 Laser User Manual...
Страница 43: ...I401 LABEL LOCATIONS PAGE 43 i401 label locations Figure 2 1 Hazard label locations...
Страница 49: ...DECLARATION OF CONFORMITY PAGE 49 Declaration of conformity Figure 2 2 i401 Declaration of conformity...
Страница 97: ...I401 OUTLINE MOUNTING DRAWINGS PAGE 97 Figure 4 29 I401 outline mounting dimensions mounting feet removed...
Страница 98: ...I401 PACKAGING INSTRUCTIONS PAGE 98 i401 packaging instructions Figure 4 30 i401 packaging instructions...
Страница 132: ...INDEX PAGE 11...