Novametrix Medical Systems 6998-00 Скачать руководство пользователя страница 1

User’s Manual

. . .simply, the leading edge

NOVAMETRIX BaseStation for Hand-Held Monitors

Содержание 6998-00

Страница 1: ...User s Manual simply the leading edge NOVAMETRIX BaseStation for Hand Held Monitors ...

Страница 2: ......

Страница 3: ......

Страница 4: ...5 TECHNOLOGY DRIVE WALLINGFORD CT U S A 06492 1 800 243 3444 203 265 7701 FAX 203 284 0753 http www novametrix com ...

Страница 5: ...User s Manual NOVAMETRIX BaseStation for Hand Held Monitors Catalog No 6998 23 00 Novametrix Medical Systems Inc PO Box 690 5 Technology Drive Wallingford Connecticut U S A 06492 June 4 1998 ...

Страница 6: ...owing specific operating instructions will void this guarantee and release Novametrix from any further guarantee obligations Copyright 1998 Novametrix Medical Systems Inc This document contains information which is proprietary and the property of Novametrix Medical Systems Inc and may not be reproduced stored in a retrieval system translated transcribed or transmitted in any form or by any means w...

Страница 7: ... Symbol Descriptions 2 Regulatory 2 Safety 3 Operational Overview 4 AC Adapter Charger External DC supply 4 Power and RS232 Serial Port Communications 5 Cleaning Instructions 7 Frequently Asked Questions 7 Specifications 9 Accessories 9 Service Policy 10 Manual Revision History Rev 00 4 Jun 98 Release ...

Страница 8: ...mounted vertical applications and can be used anywhere the TIDAL WAVE and VENT monitors are used including but not limited to the sleep lab ICU anesthesia post anesthesia emergency department respiratory care home care and pre hospital emergency Symbol Descriptions The following International Electrotechnical Commission IEC symbols appear on the BaseStation Attention Consult manual for detailed in...

Страница 9: ...r power supply may damage the monitor and BaseStation and void the warranty Refer servicing to qualified personnel There are no user serviceable parts inside Never sterilize or immerse the BaseStation in liquids Do not store the BaseStation at temperatures below 14 F 10 C or above 131 F 55 C Do not operate the BaseStation at temperatures below 50 F 10 C or above 104 F 40 C Refer to the Service Man...

Страница 10: ...indicating that external power is connected AC Adapter Charger External DC supply The BaseStation can be powered from a Novametrix AC wall adapter charger DC voltage is supplied by the adapter charger to the power input jack located on the BaseStation illuminates indicating AC Adapter Charger is Illuminates indicating external power active and a monitor is in place Green In Use LED POWER INPUT jac...

Страница 11: ...st remain in a horizontal position If the monitor is removed from the BaseStation or if the AC wall adapter charger is unplugged the monitor will be powered from its internal battery Although other connectors may physically fit do not attempt to connect any device other than the Novametrix AC Adapter Charger to the power jack on the BaseStation Doing so may damage the BaseStation and the monitor a...

Страница 12: ...ion to a host computer 1 Connect the Serial Cable PN 600075 sold separately to the RS232 Serial Port connector on the BaseStation 2 Connect the AC Adapter Charger to the POWER INPUT jack on the BaseStation It is recommended that the monitor be powered by the BaseStation using the AC Adapter Charger when downloading data from the monitor or updating software This will prevent power loss from a depl...

Страница 13: ... type battery you need the AC Adapter Charger Cat No 6879 10 or 6880 10 120VAC or 230 VAC respectively If you want to download TIDAL WAVE trend data you need the Serial Cable Cat No 600075 also known as a Mouse Extension Cable You may need a 9 to 25 pin adapter from a local electronics store if your computer has a 25 pin serial COM port connector Lastly you may want the NovaCARD for Windows softwa...

Страница 14: ...ARD Comm Port and then access the TIDAL WAVE from the File NovaCOM menu If using NovaCARD for DOS select NovaCOMM as the Input Mode in the Configuration Menu If I leave the monitor in the BaseStation too long will the battery overcharge No Circuitry within the TIDAL WAVE and VENT monitors will safely control battery charging and will prevent overcharging How can I tell that the BaseStation is rech...

Страница 15: ... 40 C 50 F to 104 F Humidity 0 90 relative humidity non condensing Transport Storage 10 to 55 C 14 131 F 10 95 relative humidity non con densing Power Requirements Use only Novametrix approved devices Catalog Number 6879 10 AC Adapter Charger Input 120 VAC Output 13VDC 1AMP Catalog Number 6880 10 AC Adapter Charger Input 230 VAC Output 13VDC 1AMP Accessories Cat No Description 6879 10 AC Adapter C...

Страница 16: ...x within 10 days in order to avoid additional charges Return materials should be cleaned as necessary and sent directly to Novametrix using the return paperwork and shipping label s provided Transferring return materials to a local sales or dealer representatives does not absolve you of your return responsibility Novametrix manufactures equipment that is generally field serviceable When repair par...

Отзывы: