![Nova Electronics MCX514 Скачать руководство пользователя страница 231](http://html1.mh-extra.com/html/nova-electronics/mcx514/mcx514_user-manual_1710400231.webp)
NOVA electronics Inc. MCX514 -
218
-
218
-
7.4.23 Split Pulse Setting 1 Reading
Code
Command
Symbol
Data Range
Data Length
(byte)
47
h
Split pulse setting 1 reading
SP1
RR6
Split length
:
2
~
65,535
4
RR7
Pulse width
:
1
~
65,534
The value set by Split pulse setting 1 command (17h) is set in read registers RR6 and RR7.
The split length is set in RR6 and the pulse width is set in RR7.
When MRm value is loaded to split pulse setting 1 (SP1) by a synchronous action, that value will be read out.
7.4.24 General Purpose Input Value Reading
Code
Command
Symbol
Data Range
Data Length
(byte)
48
h
General purpose input value reading
UI
RR7: Lower byte(PIN7
~
0)
RR6: 2 bytes (D15
~
0 in I2C
communication)
4
The axis assignment is not necessary for this command.
In I
2
C serial interface bus mode, the signal levels of D15
~
0 (pin number 1
~
8, 11
~
18) are set to read register RR6. If not in I
2
C
serial interface bus mode, read register RR6 will be 0.
When PIN7~0 (pin number 132
~
139) are used as the general purpose input, the signal levels of PIN7~0 are set to the lower 8bits
of read register RR7. The upper 8bits are 0.
PIN0
D7
D6
D5
D4
H
L
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
RR7
PIN1
PIN2
PIN3
PIN4
PIN5
PIN6
PIN7
O
O
O
O
O
O
O
O
D7
D6
D5
D4
H
L
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
RR6
D7
D6
D5
D4
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
When the signal is Low level, 0 is displayed and when the signal is Hi level, 1 is displayed.