205
-
205
-
* If a limit signal is specified, the limit signal in the search direction specified by D5(S2DR) will be
selected.
D7 S2DC
Setting for whether the deviation counter clear (nDCC) signal is output or not in the signal detection of step
2.
0: non-output, 1: output
D8 S2RC
Setting for whether the real position counter is cleared or not in the signal detection of step 2.
0: non-clear, 1: clear
D9 S2LC
Setting for whether the logical position counter is cleared or not in the signal detection of step 2.
0: non-clear, 1: clear
D10 S3EN
Setting for whether “low-speed Z-phase search” of step 3 in the automatic home search is executed or not.
0: non-execution, 1: execution
D11 S3DR
The search direction of step 3.
0: + direction, 1: − direction
D12 S3DC
Setting for whether the deviation counter clear (nDCC) signal is output or not in nSTOP2 signal detection of
step 3.
0: non-output, 1: output
D13 S3RC
Setting for whether the real position counter is cleared or not in nSTOP2 signal detection of step 3.
0: non-clear, 1: clear
D14 S3LC
Setting for whether the logical position counter is cleared or not in nSTOP2 signal detection of step 3.
0: non-clear, 1: clear
D15 S4EN
Setting for whether “high-speed offset drive” of step 4 in the automatic home search is executed or not.
0: non-execution, 1: execution
For more details of the automatic home search, see chapter 2.5 and 2.5.4.
D15~D0 will be set to 0 at reset.
7.3.5
Automatic Home Search Mode Setting 2
Code
Command
Symbol
Data Length (byte)
24
h
Automatic home search mode setting 2
H2M
2
“H2M” is the parameter setting the automatic home search mode. The stop condition for automatic home search of step 3, position
counter clear, deviation counter clear output and the timer between steps.
D7
D6
D5
D4
H
L
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
WR6
HTM0
HTM1
HTM2
HTME
DCP0
DCP1
DCP2
DCPL
RCLR
LCLR
SAND
0
0
0
0
0
Deviation Counter Clear Output
Timer between Steps
D0 SAND
When this bit is set to 1, and when nSTOP1 signal is active and nSTOP2 signal changes to active, the
operation of step 3 will stop.
This is only enabled when nSTOP1 signal is selected as the search signal of step 2, when a limit signal is
selected, it cannot be enabled.
D1 RCLR
Setting for whether the real position counter is cleared or not at the end of automatic home search.
0: non-clear, 1: clear